Filter
Filter
–
Agilent 1200 TCC SL
The Agilent 1200 Series TCC SL (G1316B) comes refurbished.SpecificationsTemperature range: 10 degrees below ambient to 100 °Cup to 100 °C: flow rates up to 2.5 ml/minTemperature stability: ± 0.05 °CTemperature accuracy ± 0.5 °CColumn capacity: Three 30 cmWarm-up/cool-down time: 5 minutes from ambient to 40 °C10 minutes from 40 - 20 °CDead volume: 6 μl right heat exchangerCommunications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other 1200 series moduleSafety maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Preis auf Anfrage
Agilent 1200 TCC SL
The Agilent 1200 Series TCC SL (G1316B) comes refurbished.SpecificationsTemperature range: 10 degrees below ambient to 100 °Cup to 100 °C: flow rates up to 2.5 ml/minTemperature stability: ± 0.05 °CTemperature accuracy ± 0.5 °CColumn capacity: Three 30 cmWarm-up/cool-down time: 5 minutes from ambient to 40 °C10 minutes from 40 - 20 °CDead volume: 6 μl right heat exchangerCommunications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other 1200 series moduleSafety maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Preis auf Anfrage
CTC HTSLC-PAL
Für Ihre HPLC und Microflow-HPLC, TOP Zustand, mit Peltierkühlung, 3 Schubladen für je 2 x Wellplate oder 2 x 49 1.5ml Vials, mit 2 Injectorvalves for analytische und prep. Proben.
Preis auf Anfrage
CTC HTSLC-PAL kurz
Für Ihre HPLC und Microflow-HPLC, TOP Zustand, mit Peltierkühlung, 3 Schubladen für je 2 x Wellplate oder 2 x 49 1.5ml Vials, mit 2 Injectorvalves for analytische und prep. Proben.
Preis auf Anfrage
ESA Corona Detector + Column Compartment
• Reliable and simple to operate.• Universal detection of nonvolatile and many semi-volatile analytes.• Four orders of magnitude dynamic range (nonlinear).• Low ng lower limits of detection.• Typically < 2% R.S.D. response variability.• Response magnitude is minimally dependent on the analyte’s chemical properties.• Broad applicability.• Isocratic and gradient compatibility.
Preis auf Anfrage
ESA Coul Array Heated Organizer 70-4470T
Temperature controlled enclosure for maintaining constant temperature and organizing coulometric array cells, pre-filters, column(s), manual injector valve, PEEK pulse dampers and biocompatible gradient mixers.Temperature range: + 5°C above ambient to 45°CTemperature accuracy: <, 0.5°C
Preis auf Anfrage
ESA Coulochem II
MODELCOULOCHEM II HPLC SYSTEM
DETECTOR (SCATTERED LIGHT)
MODELUV/VIS MODEL 522
Wavelengths, nm (OPERATING)190-800programmable
Drift, absorb/hr (DETECTOR)<,0.0002
Noise, aufs (DETECTOR)<,±0.00001
Flow cell vol, µl (DETECTOR)0.25-15
Cell pathlength, mm (DETECTOR)2-10, varies with
Avail absorb, aufs (DETECTOR)0.0005-3
Recorder output (DETECTOR)Selectable
Event marker (DETECTOR)Yes
SYSTEM CONFIGURATION
Design (SYSTEM CONFIGURATION)Modular, isocratic
std configurationDepends on config
SAMPLE INJECTORAutosampler - for details please see comments.542 Autosampler
Fixed loop or
variable (Fixed loop or)Variable
Manual or automatic (SYSTEM CONFIGURATION)Automatic
SAMPLE VOLUME, µL1
Amount of vials (SYSTEM CONFIGURATION)24,84,96
Injections/sample (SYSTEM CONFIGURATION)9
Perfomance time, min (SYSTEM CONFIGURATION)9hr 59 min 59 sec
Maximal pressure (SYSTEM CONFIGURATION)5000
Auto flushing (SYSTEM CONFIGURATION)Yes
Standard vial (SYSTEM CONFIGURATION)4types
Kind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10mL
DATA MANAGEMENT
MODELELITE EZCHROM FOR
Channels (POWER NEEDED)4
DISPLAYMS Windows-based
Chromatograms,
no. stored (Chromatograms,)Unlimited
Optional storage (DATA MANAGEMENT)Yes
PUMPESA-582
Type (CONFIGURATION)Dual piston,
Pump heads (PUMP)2
Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications.0.001-9.999
Flow increm, ml/min (PUMP)0.001
Flow precision, % (ELUENT PUMP)0.3
Flow accuracy, % (ELUENT PUMP)1
Max pressure, psi (PUMP)5000
Max/min pressure
switches (Max/min pressure)Yes
Gradient capability (PUMP)Optional with second
Solvents (PUMP)1isocratic
OTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro-
COLUMN (SPECIFICATIONS)
MODELMETA-250 : MICRODI-
Construction (ROTOR)Stainless steel
Length/internal
Diameter, mm (UMBILICAL CORD)250:150:80:150
Particle size, µm (SPECIFICATIONS)37320
Particle type (COLUMN)Silica, polymeric
Sorbent type (SPECIFICATIONS)
Reverse phase (COLUMN)C18, C8, proprietary
OTHER SPECIFICATIONS (AIR SUPPLY)Manual injector.
CE MARK (MDD) (Interference compensation)Yes
Preis auf Anfrage
ESA Coulochem II
MODELCOULOCHEM II HPLC SYSTEM
DETECTOR (SCATTERED LIGHT)
MODELUV/VIS MODEL 522
Wavelengths, nm (OPERATING)190-800programmable
Drift, absorb/hr (DETECTOR)<0.0002
Noise, aufs (DETECTOR)<±0.00001
Flow cell vol, µl (DETECTOR)0.25-15
Cell pathlength, mm (DETECTOR)2-10, varies with
Avail absorb, aufs (DETECTOR)0.0005-3
Recorder output (DETECTOR)Selectable
Event marker (DETECTOR)Yes
SYSTEM CONFIGURATION
Design (SYSTEM CONFIGURATION)Modular, isocratic
std configurationDepends on config
SAMPLE INJECTORAutosampler - for details please see comments.542 Autosampler
Fixed loop or
variable (Fixed loop or)Variable
Manual or automatic (SYSTEM CONFIGURATION)Automatic
SAMPLE VOLUME, µL1
Amount of vials (SYSTEM CONFIGURATION)24,84,96
Injections/sample (SYSTEM CONFIGURATION)9
Perfomance time, min (SYSTEM CONFIGURATION)9hr 59 min 59 sec
Maximal pressure (SYSTEM CONFIGURATION)5000
Auto flushing (SYSTEM CONFIGURATION)Yes
Standard vial (SYSTEM CONFIGURATION)4types
Kind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10mL
DATA MANAGEMENT
MODELELITE EZCHROM FOR
Channels (POWER NEEDED)4
DISPLAYMS Windows-based
Chromatograms,
no. stored (Chromatograms,)Unlimited
Optional storage (DATA MANAGEMENT)Yes
PUMPESA-582
Type (CONFIGURATION)Dual piston,
Pump heads (PUMP)2
Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications.0.001-9.999
Flow increm, ml/min (PUMP)0.001
Flow precision, % (ELUENT PUMP)0.3
Flow accuracy, % (ELUENT PUMP)1
Max pressure, psi (PUMP)5000
Max/min pressure
switches (Max/min pressure)Yes
Gradient capability (PUMP)Optional with second
Solvents (PUMP)1isocratic
OTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro-
COLUMN (SPECIFICATIONS)
MODELMETA-250 : MICRODI-
Construction (ROTOR)Stainless steel
Length/internal
Diameter, mm (UMBILICAL CORD)250:150:80:150
Particle size, µm (SPECIFICATIONS)37320
Particle type (COLUMN)Silica, polymeric
Sorbent type (SPECIFICATIONS)
Reverse phase (COLUMN)C18, C8, proprietary
OTHER SPECIFICATIONS (AIR SUPPLY)Manual injector.
CE MARK (MDD) (Interference compensation)Yes
Preis auf Anfrage
ESA Coulochem II
MODELCOULOCHEM II HPLC SYSTEM
DETECTOR (SCATTERED LIGHT)
MODELUV/VIS MODEL 522
Wavelengths, nm (OPERATING)190-800programmable
Drift, absorb/hr (DETECTOR)<0.0002
Noise, aufs (DETECTOR)<±0.00001
Flow cell vol, µl (DETECTOR)0.25-15
Cell pathlength, mm (DETECTOR)2-10, varies with
Avail absorb, aufs (DETECTOR)0.0005-3
Recorder output (DETECTOR)Selectable
Event marker (DETECTOR)Yes
SYSTEM CONFIGURATION
Design (SYSTEM CONFIGURATION)Modular, isocratic
std configurationDepends on config
SAMPLE INJECTORAutosampler - for details please see comments.542 Autosampler
Fixed loop or
variable (Fixed loop or)Variable
Manual or automatic (SYSTEM CONFIGURATION)Automatic
SAMPLE VOLUME, µL1
Amount of vials (SYSTEM CONFIGURATION)24,84,96
Injections/sample (SYSTEM CONFIGURATION)9
Perfomance time, min (SYSTEM CONFIGURATION)9hr 59 min 59 sec
Maximal pressure (SYSTEM CONFIGURATION)5000
Auto flushing (SYSTEM CONFIGURATION)Yes
Standard vial (SYSTEM CONFIGURATION)4types
Kind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10mL
DATA MANAGEMENT
MODELELITE EZCHROM FOR
Channels (POWER NEEDED)4
DISPLAYMS Windows-based
Chromatograms,
no. stored (Chromatograms,)Unlimited
Optional storage (DATA MANAGEMENT)Yes
PUMPESA-582
Type (CONFIGURATION)Dual piston,
Pump heads (PUMP)2
Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications.0.001-9.999
Flow increm, ml/min (PUMP)0.001
Flow precision, % (ELUENT PUMP)0.3
Flow accuracy, % (ELUENT PUMP)1
Max pressure, psi (PUMP)5000
Max/min pressure
switches (Max/min pressure)Yes
Gradient capability (PUMP)Optional with second
Solvents (PUMP)1isocratic
OTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro-
COLUMN (SPECIFICATIONS)
MODELMETA-250 : MICRODI-
Construction (ROTOR)Stainless steel
Length/internal
Diameter, mm (UMBILICAL CORD)250:150:80:150
Particle size, µm (SPECIFICATIONS)37320
Particle type (COLUMN)Silica, polymeric
Sorbent type (SPECIFICATIONS)
Reverse phase (COLUMN)C18, C8, proprietary
OTHER SPECIFICATIONS (AIR SUPPLY)Manual injector.
CE MARK (MDD) (Interference compensation)Yes
Preis auf Anfrage
ESA Coulochem II Model 5200A
MODELCOULOCHEM II HPLC SYSTEM
DETECTOR (SCATTERED LIGHT)
MODELUV/VIS MODEL 522
Wavelengths, nm (OPERATING)190-800programmable
Drift, absorb/hr (DETECTOR)<0.0002
Noise, aufs (DETECTOR)<±0.00001
Flow cell vol, µl (DETECTOR)0.25-15
Cell pathlength, mm (DETECTOR)2-10, varies with
Avail absorb, aufs (DETECTOR)0.0005-3
Recorder output (DETECTOR)Selectable
Event marker (DETECTOR)Yes
SYSTEM CONFIGURATION
Design (SYSTEM CONFIGURATION)Modular, isocratic
std configurationDepends on config
SAMPLE INJECTORAutosampler - for details please see comments.542 Autosampler
Fixed loop or
variable (Fixed loop or)Variable
Manual or automatic (SYSTEM CONFIGURATION)Automatic
SAMPLE VOLUME, µL1
Amount of vials (SYSTEM CONFIGURATION)24,84,96
Injections/sample (SYSTEM CONFIGURATION)9
Perfomance time, min (SYSTEM CONFIGURATION)9hr 59 min 59 sec
Maximal pressure (SYSTEM CONFIGURATION)5000
Auto flushing (SYSTEM CONFIGURATION)Yes
Standard vial (SYSTEM CONFIGURATION)4types
Kind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10mL
DATA MANAGEMENT
MODELELITE EZCHROM FOR
Channels (POWER NEEDED)4
DISPLAYMS Windows-based
Chromatograms,
no. stored (Chromatograms,)Unlimited
Optional storage (DATA MANAGEMENT)Yes
PUMPESA-582
Type (CONFIGURATION)Dual piston,
Pump heads (PUMP)2
Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications.0.001-9.999
Flow increm, ml/min (PUMP)0.001
Flow precision, % (ELUENT PUMP)0.3
Flow accuracy, % (ELUENT PUMP)1
Max pressure, psi (PUMP)5000
Max/min pressure
switches (Max/min pressure)Yes
Gradient capability (PUMP)Optional with second
Solvents (PUMP)1isocratic
OTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro-
COLUMN (SPECIFICATIONS)
MODELMETA-250 : MICRODI-
Construction (ROTOR)Stainless steel
Length/internal
Diameter, mm (UMBILICAL CORD)250:150:80:150
Particle size, µm (SPECIFICATIONS)37320
Particle type (COLUMN)Silica, polymeric
Sorbent type (SPECIFICATIONS)
Reverse phase (COLUMN)C18, C8, proprietary
OTHER SPECIFICATIONS (AIR SUPPLY)Manual injector.
CE MARK (MDD) (Interference compensation)Yes
Preis auf Anfrage
Flom Cascade Pump CP-14, Gradient Controller GE-11 / Ausstellungs-Gradientensystem
Ausstellungssystem bestehend aus:2x Cascade Pump CP-14, 0,001-10 mL/minMax. pressure: 25 MPa / 20 MPaFlow rate range: 0,001-10 mL/minFlow per stroke: 69 µLFlow accuracy: ± 0,5%Features: Active pulse reduction, Flow volume compensation, Pressure loss compensation, Set volume dispensing1x Gradient Controller GE-11An easy to program controller for gradient flow applications using 2 or more pumps.Compatible with FLOM pumps:HI-12-33HP-12-33AI seriesKP seriesSP seriesCP-14
Preis auf Anfrage
FLOM KP-12 PEEK / Ausstellungsstück
DUAL PUMP KP-12 seriesDesigned for standard HPLC applications, KP-12 offers pressure monitoring, dosing mode, stable pressure flow and pressure limit for column protection.FEATURESCompact designFlow pressure sensor for pressure monitoringPressure limiter for column protectionDosing modeNon-metal PEEK pump availableCommunication terminal for remote pump operationThree pump models available for micro, analytical and preparative applications.
Model No.KP-12-01KP-12-13KP-12-33
Max. Pressure (MPa)20(PEEK) / 25(S.Steel)20(PEEK) / 25(S.Steel)5
Flow Rate Range0.001~1.00mL/min0.01~10.00mL/min0.1~50.0mL/min
Flow Volume Per Stroke4 µl32 µI154 µI
Flow Volume Accuracy+0.3%
Special FunctionsFlow Volume Calibration, Dispensing Mode, Flow Pressure Calibration, Constant Pressure Flow
Pressure Display Accuracy+ 5%
Wetted MaterialsS.Steel or PEEK, Sapphire, Rubby, PTFE, PCTFE
Remote Input/OutputInput PUMP ON/OFF, Flow Volume (BCD) (4-20mA analogue input optional), Output: Error
Communication PortN/A
Dimensions (mm)144(H) X 79(W) X 285(D)
WeightAppr. 3.5kg
Preis auf Anfrage
FLOM SP-11 PEEK / Ausstellungsstück
PCS PUMP SP-11 seriesSingle plunger pumps with latest technology. Delivers reliable performance for simple solvent flow operation.FEATURESCompact designQuick plunger return for shorter flow interruptionPressure limiter for column protectionDosing modeNon-metal PEEK pump availableThree pump models available for micro, analytical and preparative applications
Model No.SP-12-MSP-12-12SP-12-13SP-12-32SP-12-33
Max. Pressure (MPa)20MPa20MPa10MPa5MPa2MPa
Flow Rate Range0.01~1.00mL/min0.01~2.00mL/min0.1~5.00mL/min0.1~10.0mL/min0.1~20.0mL/min
Plunger Diameterφ 2φ 3.27 φ
Plunger Stroke2mm2mm4mm2mm4mm
Flow Volume Per Stroke8µl16µl32µl77µl154µl
Flow Volume Accuracy+ 0.5%
Special FunctionsPulse Reduction Mode, Dispensing Mode (0.01 or 0.1-1000mL)
Wetted MaterialsS.Steel or PEEK, Sapphire, Rubby, PTFE, PCTFE
Remote Input/OutputInput: PUMP ON/OFF, Flow Volume (BCD) (4-20mA analogue input optional) Output: Error
Dimensions (mm)144(H) X 79(W) X 285(D)
WeightAppr. 3.0kg
Preis auf Anfrage
FLOM SP-12 STEEL / Ausstellungsstück
PCS PUMP SP-12 seriesSingle plunger pumps with latest technology. Delivers reliable performance for simple solvent flow operation.FEATURESCompact designQuick plunger return for shorter flow interruptionFlow pressure sensor for real-time pressure monitoringPressure limiter for column protectionDosing modeNon-metal PEEK pump availableThree pump models available for micro, analytical and preparative applications
Model No.SP-12-MSP-12-12SP-12-13SP-12-32SP-12-33
Max. Pressure (MPa)20MPa20MPa10MPa5MPa2MPa
Flow Rate Range0.01~1.00mL/min0.01~2.00mL/min0.1~5.00mL/min0.1~10.0mL/min0.1~20.0mL/min
Plunger Diameterφ 2φ 3.27 φ
Plunger Stroke2mm2mm4mm2mm4mm
Flow Volume Per Stroke8µl16µl32µl77µl154µl
Flow Volume Accuracy+ 0.5%
Special FunctionsFlow Volume Calibration, Flow Pressure Calibration, Flow Pressure Limit, Pulse ReductionMode, Dispensing Mode (0.01 or 0.1-1000mL)
Wetted MaterialsS.Steel or PEEK, Sapphire, Rubby, PTFE, PCTFE
Remote Input/OutputInput: PUMP ON/OFF, Flow Volume (BCD) (4-20mA analogue input optional) Output: Error
Dimensions (mm)144(H) X 79(W) X 285(D)
WeightAppr. 3.0kg
Preis auf Anfrage
FLOM Vacuum Degasser Gastorr 154
4 linesFlow up to 10 ml/min, optimal below 3 ml/min
Preis auf Anfrage
Varian PrepStar SD2 200ml/min
Das PrepStar SD-2-Lösungsmitteldosiermodul wurde entwickelt, um die Bedürfnisse von Wissenschaftlern und Ingenieuren zu erfüllen, die die Fähigkeit benötigen Lösungsmittel mit hohen Durchflussraten (bis zu 800 mL/min) bei hohen Drücken.SpezifikationenAllgemeine Spezifikationen- Kompakte, modulare Tischausführung- Maximaler Betriebsdruck 800 - 2500 psi (165 bar).Lösemittelfördermodul Pumpe- Beinhaltet alle oben aufgeführten allgemeinen Spezifikationen- Duplex-Zirkoniumdioxid-Kolbenpumpe- Pumpenköpfe aus Titan- Durchflussrate: SD-2 80 bis 800 mL/min (obere Flussratengrenze ist abhängig von der Viskosität des Lösungsmittels)- Drucküberwachung (Anzeige auf dem Bedienfeld)Installationsanforderungen- Stromversorgung: 230 Vac, 50/60 Hz, 1000 VAPhysikalische Spezifikationen- Modul zur Lösungsmittelabgabe: 11,5" B x 7,75 H x 20,25" T (29,2 cm x 19,7 cm x 57,5 cm)- Gewicht: ungefähr 27 kg (60 lb).
Preis auf Anfrage
Varian SD1 HPLC System
Varian SD1 HPLC System bestehend aus:Rainin FC-1PrepStar SD1 PumpPrepStar SD1 PumpePrepStar Solvent Delivery Module Model 218Varian ProStarHP xw4400 WorkstationDell Monitor
Preis auf Anfrage