Filter
Filter
–
Agilent 1200 ALS
This Agilent 1200 Series (G1329A) comes refurbished.Performance SpecificationsPressure: Operatiing range 0- 40 MPa (0 - 400 bar, 0 - 5900 psi)GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errorsCommunications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number outputSafety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and displayInjections range: 0.1 – 100 μl in 0.1 μl increments Up to 1500 μl with multiple draw (hardware modification required)Replicate injections: 1- 99 from one vialPrecision: <0.25%RSDfrom5–100μl,<1%RSD1–5μl variable volumeMinimum sample volume: 1 μl from 5 μl sample in 100 μl microvial, or 1 μl from 10 μl sample in 300 μl microvialCarryover: Typically < 0.1%, < 0.05% with external needle cleaningSample viscosity range 0.2 - 50 cpReplicate injections per vial: 1 - 99Sample capacitcy: 100 × 2-ml vials in 1 tray40 × 2-ml vials in 1⁄2 tray15 × 6-ml vials in 1⁄2 tray (Agilent vials only)Injection cycle time: Typically 50 s depending on draw speed an injection volume
Price on request
Agilent 1200 FC / ALS Therm
The Agilent 1200 Series FC/ALS Term (G1330B) comes refurbished.SpecificationsTemperature range: setable from 4 °C to 40 °C in 1 °C incrementsTemperature accuracy at ambient temperatures < 25 °C and humidity < 50%:- 1°C to + 4 °C at a setpoint of 4 °CTemperature accuracy at ambient temperatures > 25 °C and/or humidity > 50%:- 1°C to + 5 °C at a setpoint of 4 °C
Price on request
Agilent 1200 FC / ALS Therm
The Agilent 1200 Series FC/ALS Term (G1330B) comes refurbished.SpecificationsTemperature range: setable from 4 °C to 40 °C in 1 °C incrementsTemperature accuracy at ambient temperatures < 25 °C and humidity < 50%:- 1°C to + 4 °C at a setpoint of 4 °CTemperature accuracy at ambient temperatures > 25 °C and/or humidity > 50%:- 1°C to + 5 °C at a setpoint of 4 °C
Price on request
Agilent 1200 FC/ALS Therm
The Agilent 1200 Series FC/ALS Term (G1330B) comes refurbished.SpecificationsTemperature range: setable from 4 °C to 40 °C in 1 °C incrementsTemperature accuracy at ambient temperatures < 25 °C and humidity < 50%:- 1°C to + 4 °C at a setpoint of 4 °CTemperature accuracy at ambient temperatures > 25 °C and/or humidity > 50%:- 1°C to + 5 °C at a setpoint of 4 °C
Price on request
Agilent 1200 HPS SL
This Agilent 1200 HPS SL (G1367C) comes refurbished.SpecificationsIncreased pressure range enabling the use of today\'s column technology (sub-two-micron columns) with the Agilent 1200 Rapid Resolution system.High speed with lowest carry-over by flow through design.Increased sample injection speed for high sample throughput.Increased productivity by using overlapped injection mode.Minimal delay volumes for rapid gradients and fast equilibration when bypassing the autosampler after sample injection.Flexible and convenient sample handling with different types of sample containers, such as vials and well plates. Using 384-well plates allows you to process up to 768 samples unattended.Peltier temperature control from 4 to 40° C for thermally-labile samples (upgrade from non-thermostted to thermostatted version possible).
Price on request
CTC HTSLC-PAL
Für Ihre HPLC und Microflow-HPLC, TOP Zustand, mit Peltierkühlung, 3 Schubladen für je 2 x Wellplate oder 2 x 49 1.5ml Vials, mit 2 Injectorvalves for analytische und prep. Proben.
Price on request
CTC HTSLC-PAL short
Für Ihre HPLC und Microflow-HPLC, TOP Zustand, mit Peltierkühlung, 3 Schubladen für je 2 x Wellplate oder 2 x 49 1.5ml Vials, mit 2 Injectorvalves for analytische und prep. Proben.
Price on request