Filter
Filter
–
LTQ Orbitrap XL Hybrid Ion Trap Mass Spectrometer
€33,000.00*
LC/MSn high resolutionIon Max ESI Source & HCD Collision CellTested, with warranty. Spezifikationen:Routine FT mass accuracy60,000 resolution at 1 Hz scan cycleWide dynamic rangeParallel MS and MSn analysisMultiple dissociation techniques: CID, PQD and HCDMass Range m/z 50-2000, m/z 200-4000Resolution 60,000 at m/z 400 at a scan rate of 1 Hz,min. resolution 7,500 max. resolution >100,000 at m/z 400Mass Accuracy < 3 ppm external calibration, < 2 ppm internal calibrationSensitivity sub-femtomol range for peptidesDynamic Range > 4,000 within a single scanMS Scan Power MSn , for n = 1 through 10Price plus installation.
LTQ Orbitrap XL Hybrid Ion Trap Mass Spectrometer
€45,000.00*
Inklusive Ion Max ESI Source, HCD Collision Cell, Thermoflex 900 Chiller und Vorvakuumpumpen.Komplett geprüft mit 3 Monaten GewährleistungSpezifikationen:Routine FT mass accuracy100,000 resolution at 1 Hz scan cycleWide dynamic rangeParallel MS and MSn analysisMultiple dissociation techniques: CID, PQD and HCDMass Range m/z 50-2000, m/z 200-4000Resolution 60,000 at m/z 400 at a scan rate of 1 Hz*,min. resolution 7,500 max. resolution 100,000 at m/z 400*Mass Accuracy < 3 ppm external calibration, < 1 ppm internal calibration*Sensitivity sub-femtomol range for peptidesDynamic Range > 4,000 within a single scanMS Scan Power MSn , for n = 1 through 10*Die Spezifikationen von refurbished Geräten können abweichen!Baujahr 2013.Inklusive Ion Max ESI Source, HCD Collision Cell, Thermoflex 900 Chiller und Vorvakuumpumpen.Komplett geprüft mit 3 Monaten GewährleistungSpezifikationen:Routine FT mass accuracy100,000 resolution at 1 Hz scan cycleWide dynamic rangeParallel MS and MSn analysisMultiple dissociation techniques: CID, PQD and HCDMass Range m/z 50-2000, m/z 200-4000Resolution 60,000 at m/z 400 at a scan rate of 1 Hz*,min. resolution 7,500 max. resolution 100,000 at m/z 400*Mass Accuracy < 3 ppm external calibration, < 1 ppm internal calibration*Sensitivity sub-femtomol range for peptidesDynamic Range > 4,000 within a single scanMS Scan Power MSn , for n = 1 through 10*Die Spezifikationen von refurbished Geräten können abweichen!Baujahr 2013.Price plus installation.
Thermo Fisher Q-Exactive
The Thermo Fisher Q Exactive mass spectrometer, manufactured in 2016, is in mint condition and is available as a refurbished instrument to manufacturer specification. This thoroughly tested instrument offers excellent performance and reliability. It is equipped with advanced Orbitrap mass analyzer technology and offers unparalleled resolution and sensitivity for various proteomics applications. Ideal for laboratories requiring fast and accurate mass spectrometry, this device offers robust identification and quantification capabilities.Device specifications - Scanning speed up to 12 Hz - Resolution up to 140,000 (FWHM) at m/z 200- Mass accuracy: With external calibration: < 3 ppm, with internal calibration: < 1 ppm- Mass range: 50 to 6,000 m/z - Data Dependent Acquisition (DDA) strategy for bottom-up and top-down proteome analyses- Dynamic retention time adjustment in PRM for improved targeted quantification- Dynamic range >5000:1- Accelerated High Energy Collision Dissociation (aHCD)
Price on request