AB Sciex API 4000
Used and refurbished to manufacturers specifications Sensitive results for drug developmentRobust, high-throughput efficiencyLow detection limits for trace analysisHigh-quality results for quantitation and precise identification of low abundance compounds, even in matrices like clinical samples, pesticide/drug residues, forensic toxicology samples and environmental samples Mass Accuracy / Stability 0.1 Da over 8 hours, 0.15 Da over 24 hoursMass Range 5-3,000Polarity Switching Time 700 msScan Speed (Quad) 24,000 Da/secScan Types Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRMSensitivity MRM Mode 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Price on request
AB Sciex TripeTOF 5600
condition Overhauled, tested, calibrated, top condition Year of manufacture 2007 Fulfills all manufacturer specifications Wide range of possible applications Resolution of 25,000 FWHM with a mass of 100 m/z, up to 40,000 FWHM at a mass of 950 m/z and a scan rate of 100 spectra per second
Price on request
Agilent 1200 ALS
This Agilent 1200 Series (G1329A) comes refurbished.Performance SpecificationsPressure: Operatiing range 0- 40 MPa (0 - 400 bar, 0 - 5900 psi)GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errorsCommunications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number outputSafety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and displayInjections range: 0.1 – 100 μl in 0.1 μl increments Up to 1500 μl with multiple draw (hardware modification required)Replicate injections: 1- 99 from one vialPrecision: <0.25%RSDfrom5–100μl,<1%RSD1–5μl variable volumeMinimum sample volume: 1 μl from 5 μl sample in 100 μl microvial, or 1 μl from 10 μl sample in 300 μl microvialCarryover: Typically < 0.1%, < 0.05% with external needle cleaningSample viscosity range 0.2 - 50 cpReplicate injections per vial: 1 - 99Sample capacitcy: 100 × 2-ml vials in 1 tray40 × 2-ml vials in 1⁄2 tray15 × 6-ml vials in 1⁄2 tray (Agilent vials only)Injection cycle time: Typically 50 s depending on draw speed an injection volume
Price on request
Agilent 1200 Bin Pump
This is a refurbished Agilent 1200 Series G1312B Binary Pump SL.Specifications:Weight 15.5 kg (34 lbs)Dimensions (width — depth — height): 180 x 345 x 435 mm (7 x 13.5 x 17 inches)Flow range: 0.05°C 5.0 mL/mFlow accuracy: ± 1% or 10 µL/min, what ever is greaterPressure: Operating range 0°C 600 bar (0°C 7800 psi) up to 5ml/min
Price on request
Agilent 1200 Bin Pump SL
This is a refurbished Agilent 1200 Series G1312B Binary Pump SL.Specifications:Weight 15.5 kg (34 lbs)Dimensions (width — depth — height): 180 x 345 x 435 mm (7 x 13.5 x 17 inches)Flow range: 0.05°C 5.0 mL/mFlow accuracy: ± 1% or 10 µL/min, what ever is greaterPressure: Operating range 0°C 600 bar (0°C 7800 psi) up to 5ml/min
Price on request
Agilent 1200 DAD
Detector type1024-element diode array
Light sourceDeuterium and tungsten lamp
Short-term noise< ± 0.8 x 10 -5 AU at 254 nm and at 750 nm
Drift< 0.9 x 10 -3 AU/hr, at 254 nm
Linearity>2 AU upper limit
Wavelength range190-950 nm
Wavelength accuracy± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
Slit widthProgrammable: 1, 2, 4, 8, 16 nm
Diode width< 1 nm
Wavelength bunchingProgrammable, 2 - 400 nm, in steps of 1 nm
Flow cells
Standard13-µL volume, 10 mm cell path length, 120 bar (1760 psi) pressure maximum
Semi-micro5-µL volume, 6 mm cell path length, 120 bar (1760 psi) pressure maximum
Micro2-µL volume, 3 mm cell path length, 400 bar (5880 psi) pressure maximum
Semi-nano500-nanoliter volume 10-mm cell path length, 50 bar (735 psi) pressure maximum
Nano80 nanoliter volume., 6-mm cell path length, 50 bar (735 psi) pressure maximum
Preparative3-mm cell path length, 120 bar (1760 psi) pressur maximum0.3-mm cell path lenght, 20 bar (294 psi) pressure maximum, quartz0.06-mm cell path length, 20 bar (294 psi) pressure maximum, quartz
High pressure1.7-µL volume, 6-mm cell path length, 400 bar (5880 psi) pressure maximum
Time programmableWavelength, polarity, peak width, lamp bandwidth, autobalance,WL range, threshold, spectra storage mode
Spectral toolsData analysis software for spectra evaluation, including spectral libraries and peak purity functions
Analog outputRecorder/integrator 100 mV or 1 V, 2 outputs
GLPData recovery card to prevent data losses. RFID for electronics records of flow cell and UV lamp conditions (path length, volume, product number, serial number, test passed, usage). Electronic records of maintenance and errors. Early maintenance feedback (EMF) for continuous tracking of instrument usage, display of feedback messages if preset limits are exceeded. Verification of wavelength accuracy with built-in holmium oxide filter.
Price on request
Agilent 1200 DAD SL
This used Agilent 1200 series DAD SL (G1315C) comes refurbished.
Detector type1024-element diode array
Light sourceDeuterium and tungsten lamp
Short-term noise< ± 0.8 x 10 -5 AU at 254 nm and at 750 nm
Drift< 0.9 x 10 -3 AU/hr, at 254 nm
Linearity>2 AU upper limit
Wavelength range190-950 nm
Wavelength accuracy± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
Slit widthProgrammable: 1, 2, 4, 8, 16 nm
Diode width< 1 nm
Wavelength bunchingProgrammable, 2 - 400 nm, in steps of 1 nm
Flow cells
Standard13-µL volume, 10 mm cell path length, 120 bar (1760 psi) pressure maximum
Semi-micro5-µL volume, 6 mm cell path length, 120 bar (1760 psi) pressure maximum
Micro2-µL volume, 3 mm cell path length, 400 bar (5880 psi) pressure maximum
Semi-nano500-nanoliter volume 10-mm cell path length, 50 bar (735 psi) pressure maximum
Nano80 nanoliter volume., 6-mm cell path length, 50 bar (735 psi) pressure maximum
Preparative3-mm cell path length, 120 bar (1760 psi) pressur maximum0.3-mm cell path lenght, 20 bar (294 psi) pressure maximum, quartz0.06-mm cell path length, 20 bar (294 psi) pressure maximum, quartz
High pressure1.7-µL volume, 6-mm cell path length, 400 bar (5880 psi) pressure maximum
Time programmableWavelength, polarity, peak width, lamp bandwidth, autobalance,WL range, threshold, spectra storage mode
Spectral toolsData analysis software for spectra evaluation, including spectral libraries and peak purity functions
Analog outputRecorder/integrator 100 mV or 1 V, 2 outputs
GLPData recovery card to prevent data losses. RFID for electronics records of flow cell and UV lamp conditions(path length, volume, product number, serial number, test passed, usage).Electronic records of maintenance and errors. Early maintenance feedback (EMF) for continuous tracking of instrument usage,display of feedback messages if preset limits are exceeded. Verification of wavelength accuracy with built-in holmium oxide filter.
Price on request
Agilent 1200 Degasser
This Agilent 1200 Series Micro Vacuum Degasser (G1379B) comes refurbished.Specifications:Maximum flow rate: 0 – 5 ml/min per channelNumber of channels: 4Internal volume per channel: Typically 1 ml per channelpH range: 1 – 14RS232 output: For diagnosis purposeMaterial in contact with Solvents: PTFE, FEP, PEEKWeight: 7 kg (16 lbs)Dimensions: 13.5 x 17 x 3.1 in. (34.5 x 43.5 x 8 cm)Line voltage: 100 – 240 VAC, ± 10% Wide-ranging capabilityLine frequency: 50 or 60 Hz, ± 5%Power consumption: 30 VA / 30 W / 102 BTU MaximumAmbient operating temperature: 0 – 55 °C (32 – 131 °F)Ambient non-operating temperature: -40–70 °C (-4–158 °F)Humidity: < 95%, at 25–40 °C (77–104 °F) Non-condensingOperating Altitude: Up to 2000 m (6500 ft)Non-operating altitude: Up to 4600 m (14950 ft) For storing the moduleSafety standards: IEC, CSA, ULInstallation Category II, Pollution Degree 2
Price on request
Agilent 1200 Degasser
This Agilent 1200 Series Micro Vacuum Degasser (G1379B) comes refurbished.Specifications:Maximum flow rate: 0 – 5 ml/min per channelNumber of channels: 4Internal volume per channel: Typically 1 ml per channelpH range: 1 – 14RS232 output: For diagnosis purposeMaterial in contact with Solvents: PTFE, FEP, PEEKWeight: 7 kg (16 lbs)Dimensions: 13.5 x 17 x 3.1 in. (34.5 x 43.5 x 8 cm)Line voltage: 100 – 240 VAC, ± 10% Wide-ranging capabilityLine frequency: 50 or 60 Hz, ± 5%Power consumption: 30 VA / 30 W / 102 BTU MaximumAmbient operating temperature: 0 – 55 °C (32 – 131 °F)Ambient non-operating temperature: -40–70 °C (-4–158 °F)Humidity: < 95%, at 25–40 °C (77–104 °F) Non-condensingOperating Altitude: Up to 2000 m (6500 ft)Non-operating altitude: Up to 4600 m (14950 ft) For storing the moduleSafety standards: IEC, CSA, ULInstallation Category II, Pollution Degree 2
Price on request
Agilent 1200 Degasser
This Agilent 1200 Series Micro Vacuum Degasser (G1379B) comes refurbished.Specifications:Maximum flow rate: 0 – 5 ml/min per channelNumber of channels: 4Internal volume per channel: Typically 1 ml per channelpH range: 1 – 14RS232 output: For diagnosis purposeMaterial in contact with Solvents: PTFE, FEP, PEEKWeight: 7 kg (16 lbs)Dimensions: 13.5 x 17 x 3.1 in. (34.5 x 43.5 x 8 cm)Line voltage: 100 – 240 VAC, ± 10% Wide-ranging capabilityLine frequency: 50 or 60 Hz, ± 5%Power consumption: 30 VA / 30 W / 102 BTU MaximumAmbient operating temperature: 0 – 55 °C (32 – 131 °F)Ambient non-operating temperature: -40–70 °C (-4–158 °F)Humidity: < 95%, at 25–40 °C (77–104 °F) Non-condensingOperating Altitude: Up to 2000 m (6500 ft)Non-operating altitude: Up to 4600 m (14950 ft) For storing the moduleSafety standards: IEC, CSA, ULInstallation Category II, Pollution Degree 2
Price on request
Agilent 1200 Degasser
This Agilent 1200 Series Micro Vacuum Degasser (G1379B) comes refurbished.Specifications:Maximum flow rate: 0 – 5 ml/min per channelNumber of channels: 4Internal volume per channel: Typically 1 ml per channelpH range: 1 – 14RS232 output: For diagnosis purposeMaterial in contact with Solvents: PTFE, FEP, PEEKWeight: 7 kg (16 lbs)Dimensions: 13.5 x 17 x 3.1 in. (34.5 x 43.5 x 8 cm)Line voltage: 100 – 240 VAC, ± 10% Wide-ranging capabilityLine frequency: 50 or 60 Hz, ± 5%Power consumption: 30 VA / 30 W / 102 BTU MaximumAmbient operating temperature: 0 – 55 °C (32 – 131 °F)Ambient non-operating temperature: -40–70 °C (-4–158 °F)Humidity: < 95%, at 25–40 °C (77–104 °F) Non-condensingOperating Altitude: Up to 2000 m (6500 ft)Non-operating altitude: Up to 4600 m (14950 ft) For storing the moduleSafety standards: IEC, CSA, ULInstallation Category II, Pollution Degree 2
Price on request
Agilent 1200 FC / ALS Therm
The Agilent 1200 Series FC/ALS Term (G1330B) comes refurbished.SpecificationsTemperature range: setable from 4 °C to 40 °C in 1 °C incrementsTemperature accuracy at ambient temperatures < 25 °C and humidity < 50%:- 1°C to + 4 °C at a setpoint of 4 °CTemperature accuracy at ambient temperatures > 25 °C and/or humidity > 50%:- 1°C to + 5 °C at a setpoint of 4 °C
Price on request
Agilent 1200 FC / ALS Therm
The Agilent 1200 Series FC/ALS Term (G1330B) comes refurbished.SpecificationsTemperature range: setable from 4 °C to 40 °C in 1 °C incrementsTemperature accuracy at ambient temperatures < 25 °C and humidity < 50%:- 1°C to + 4 °C at a setpoint of 4 °CTemperature accuracy at ambient temperatures > 25 °C and/or humidity > 50%:- 1°C to + 5 °C at a setpoint of 4 °C
Price on request
Agilent 1200 FC/ALS Therm
The Agilent 1200 Series FC/ALS Term (G1330B) comes refurbished.SpecificationsTemperature range: setable from 4 °C to 40 °C in 1 °C incrementsTemperature accuracy at ambient temperatures < 25 °C and humidity < 50%:- 1°C to + 4 °C at a setpoint of 4 °CTemperature accuracy at ambient temperatures > 25 °C and/or humidity > 50%:- 1°C to + 5 °C at a setpoint of 4 °C
Price on request
Agilent 1200 HPS SL
This Agilent 1200 HPS SL (G1367C) comes refurbished.SpecificationsIncreased pressure range enabling the use of today\'s column technology (sub-two-micron columns) with the Agilent 1200 Rapid Resolution system.High speed with lowest carry-over by flow through design.Increased sample injection speed for high sample throughput.Increased productivity by using overlapped injection mode.Minimal delay volumes for rapid gradients and fast equilibration when bypassing the autosampler after sample injection.Flexible and convenient sample handling with different types of sample containers, such as vials and well plates. Using 384-well plates allows you to process up to 768 samples unattended.Peltier temperature control from 4 to 40° C for thermally-labile samples (upgrade from non-thermostted to thermostatted version possible).
Price on request
Agilent 1200 TCC SL
The Agilent 1200 Series TCC SL (G1316B) comes refurbished.SpecificationsTemperature range: 10 degrees below ambient to 100 °Cup to 100 °C: flow rates up to 2.5 ml/minTemperature stability: ± 0.05 °CTemperature accuracy ± 0.5 °CColumn capacity: Three 30 cmWarm-up/cool-down time: 5 minutes from ambient to 40 °C10 minutes from 40 - 20 °CDead volume: 6 μl right heat exchangerCommunications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other 1200 series moduleSafety maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Price on request
Agilent 1200 TCC SL
The Agilent 1200 Series TCC SL (G1316B) comes refurbished.SpecificationsTemperature range: 10 degrees below ambient to 100 °Cup to 100 °C: flow rates up to 2.5 ml/minTemperature stability: ± 0.05 °CTemperature accuracy ± 0.5 °CColumn capacity: Three 30 cmWarm-up/cool-down time: 5 minutes from ambient to 40 °C10 minutes from 40 - 20 °CDead volume: 6 μl right heat exchangerCommunications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other 1200 series moduleSafety maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Price on request
Cascade Pump CP-14, Gradient Controller GE-11 / Ausstellungs-Gradientensystem
Ausstellungssystem bestehend aus:2x Cascade Pump CP-14, 0,001-10 mL/minMax. pressure: 25 MPa / 20 MPaFlow rate range: 0,001-10 mL/minFlow per stroke: 69 µLFlow accuracy: ± 0,5%Features: Active pulse reduction, Flow volume compensation, Pressure loss compensation, Set volume dispensing1x Gradient Controller GE-11An easy to program controller for gradient flow applications using 2 or more pumps.Compatible with FLOM pumps:HI-12-33HP-12-33AI seriesKP seriesSP seriesCP-14