THERMO Orbitrap Fusion LUMOS ETD
€220,000.00
Product number:
100471
Orbitrap Tribrid HRMS instrument, manufactured in 2017
Specifications
Mass range:
m/z 50–2,000, m/z 200–4,000, up to m/z 6,000 without precursor ion
OTMS resolution:
15,000–500,000 (FWHM) at m/z 200
Scan rate:
OTMSn up to 20 Hz, ITMSn up to 20 Hz
OTMS mass accuracy:
< 3 ppm RMS with external calibration, < 1 ppm RMS with internal calibration
MS/MS electrospray ionization (ESI) ion trap sensitivity: 2 μL of a 50 fg/μL solution of reserpine
(total 100 femtograms), injected at a flow rate of 500 μL/min, produces a minimum signal-to-noise ratio of 200:1 for the transition of the isolated protonated molecular ions at m/z 609 to the two largest products, m/z 397 and m/z 448, when the mass spectrometer is operated with unit resolution in full-scan MS/MS mode, m/z 165–615. An HESI III probe is required for the test.
Dynamic range:
> 5,000 within a single OTMS spectrum
MS scan capability: MSn, for n = 1 to 10
Synchronous precursor isolation, up to 20 precursors per MSn scan
Multiplexing using the ion routing multipole
Up to 10 precursors per scan using the quadrupole mass filter
Polarity switching:
full cycle in < 1.1 s (one full scan in positive mode and one full scan in negative mode at a resolution setting of 30,000)
ETD efficiency: ETD fragmentation efficiency of >15% (infusion of 1 pmol/μL angiotensin at 3 μL/min)
refurbished, incl. forepump, control computer, LED monitor
(HPLC / UPLC / nanoLC optional upon request)
Specifications
Mass range:
m/z 50–2,000, m/z 200–4,000, up to m/z 6,000 without precursor ion
OTMS resolution:
15,000–500,000 (FWHM) at m/z 200
Scan rate:
OTMSn up to 20 Hz, ITMSn up to 20 Hz
OTMS mass accuracy:
< 3 ppm RMS with external calibration, < 1 ppm RMS with internal calibration
MS/MS electrospray ionization (ESI) ion trap sensitivity: 2 μL of a 50 fg/μL solution of reserpine
(total 100 femtograms), injected at a flow rate of 500 μL/min, produces a minimum signal-to-noise ratio of 200:1 for the transition of the isolated protonated molecular ions at m/z 609 to the two largest products, m/z 397 and m/z 448, when the mass spectrometer is operated with unit resolution in full-scan MS/MS mode, m/z 165–615. An HESI III probe is required for the test.
Dynamic range:
> 5,000 within a single OTMS spectrum
MS scan capability: MSn, for n = 1 to 10
Synchronous precursor isolation, up to 20 precursors per MSn scan
Multiplexing using the ion routing multipole
Up to 10 precursors per scan using the quadrupole mass filter
Polarity switching:
full cycle in < 1.1 s (one full scan in positive mode and one full scan in negative mode at a resolution setting of 30,000)
ETD efficiency: ETD fragmentation efficiency of >15% (infusion of 1 pmol/μL angiotensin at 3 μL/min)
refurbished, incl. forepump, control computer, LED monitor
(HPLC / UPLC / nanoLC optional upon request)