Filter products
Binary gradient pump with degasser, max. 600 barVial sampler, p max. 600 bar - without thermostatColumn oven, max. 80°C, 6µL dead volume, for 1 column max. 25cmDAD detector G1315D, 80 Hz with standard flow cell G1315-60022Accessory kit G4290-68755NEW, display model
2-position/6-port injection valve 600 barNew & in original packagingDelivery with cable, but without capillary.
Used Agilent Type 1260 Quaternary Pump for versatile HPLC methods.
Columns up to 300 mm long and OD up to 10 mmTemperature 5 °C to 150 °C or -15 °C to 100 °CPrice does not include shipping cost.Item in stock and available.All devices leave our premises tested and in working order.
For your HPLC and Microflow-HPLC for automated chromatography, TOP condition, with Peltier cooling, 3 drawers for 2 x wellplates or 2 x 49 1.5ml vials, with 2 injector valves for analytical and prep. samples.
For your HPLC and microflow HPLC for short paths in automation, TOP condition, with Peltier cooling, 3 drawers each for 2 x wellplates or 2 x 49 1.5 ml vials, with 2 injector valves for analytical and prep. samples.
• Reliable and simple to operate.• Universal detection of nonvolatile and many semi-volatile analytes.• Four orders of magnitude dynamic range (nonlinear).• Low ng lower limits of detection.• Typically < 2% R.S.D. response variability.• Response magnitude is minimally dependent on the analyte’s chemical properties.• Broad applicability.• Isocratic and gradient compatibility.
The ESA Coularray Detector Model 5600A is a Coulometric Multi-Electrode Electrochemical Detector for High Performance Liquid Chromatography (HPLC). The instrument is designed to detect and quantitate trace levels of electroactive compounds in complex matrices. A typical application is the qualitative and quantitative analysis of a broad range of biogenic amines in biological tissues.
Temperature controlled enclosure for maintaining constant temperature and organizing coulometric array cells, pre-filters, column(s), manual injector valve, PEEK pulse dampers and biocompatible gradient mixers.Temperature range: + 5°C above ambient to 45°CTemperature accuracy: < 0.5°C
MODELCOULOCHEM II HPLC SYSTEMDETECTOR (SCATTERED LIGHT) MODELUV/VIS MODEL 522Wavelengths, nm (OPERATING)190800 programmableDrift, absorb/hr (DETECTOR)<,0.0002Noise, aufs (DETECTOR)<,±0.00001Flow cell vol, µl (DETECTOR)0.2515Cell pathlength, mm (DETECTOR)210, varies withAvail absorb, aufs (DETECTOR)0.00053Recorder output (DETECTOR)SelectableEvent marker (DETECTOR)YesSYSTEM CONFIGURATION Design (SYSTEM CONFIGURATION)Modular, isocraticstd configurationDepends on configSAMPLE INJECTORAutosampler - for details please see comments. 542 AutosamplerFixed loop or variable (Fixed loop or)VariableManual or automatic (SYSTEM CONFIGURATION)AutomaticSAMPLE VOLUME, µL1Amount of vials (SYSTEM CONFIGURATION)24,84,96Injections/sample (SYSTEM CONFIGURATION)9Perfomance time, min (SYSTEM CONFIGURATION)9 hr 59 min 59 secMaximal pressure (SYSTEM CONFIGURATION)5000Auto flushing (SYSTEM CONFIGURATION)YesStandard vial (SYSTEM CONFIGURATION)4 typesKind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10 mLDATA MANAGEMENT MODELELITE EZCHROM FORChannels (POWER NEEDED)4DISPLAYMS WindowsbasedChromatograms, no. stored (Chromatograms,)UnlimitedOptional storage (DATA MANAGEMENT)YesPUMPESA582Type (CONFIGURATION)Dual piston,Pump heads (PUMP)2Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications. 0.0019.999Flow increm, ml/min (PUMP)0.001Flow precision, % (ELUENT PUMP)0.3Flow accuracy, % (ELUENT PUMP)1Max pressure, psi (PUMP)5000Max/min pressure switches (Max/min pressure)YesGradient capability (PUMP)Optional with secondSolvents (PUMP)1 isocraticOTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro-COLUMN (SPECIFICATIONS) MODELMETA250 : MICRODI-Construction (ROTOR)Stainless steelLength/internal Diameter, mm (UMBILICAL CORD)250: 150: 80: 150Particle size, µm (SPECIFICATIONS)37320Particle type (COLUMN)Silica, polymericSorbent type (SPECIFICATIONS) Reverse phase (COLUMN)C18, C8, proprietaryOTHER SPECIFICATIONS (AIR SUPPLY)Manual injector.CE MARK (MDD) (Interference compensation)Yes
MODELCOULOCHEM II HPLC SYSTEMDETECTOR (SCATTERED LIGHT) MODELUV/VIS MODEL 522Wavelengths, nm (OPERATING)190800 programmableDrift, absorb/hr (DETECTOR)<0.0002Noise, aufs (DETECTOR)<±0.00001Flow cell vol, µl (DETECTOR)0.2515Cell pathlength, mm (DETECTOR)210, varies withAvail absorb, aufs (DETECTOR)0.00053Recorder output (DETECTOR)SelectableEvent marker (DETECTOR)YesSYSTEM CONFIGURATION Design (SYSTEM CONFIGURATION)Modular, isocraticstd configurationDepends on configSAMPLE INJECTORAutosampler - for details please see comments. 542 AutosamplerFixed loop or variable (Fixed loop or)VariableManual or automatic (SYSTEM CONFIGURATION)AutomaticSAMPLE VOLUME, µL1Amount of vials (SYSTEM CONFIGURATION)24,84,96Injections/sample (SYSTEM CONFIGURATION)9Perfomance time, min (SYSTEM CONFIGURATION)9 hr 59 min 59 secMaximal pressure (SYSTEM CONFIGURATION)5000Auto flushing (SYSTEM CONFIGURATION)YesStandard vial (SYSTEM CONFIGURATION)4 typesKind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10 mLDATA MANAGEMENT MODELELITE EZCHROM FORChannels (POWER NEEDED)4DISPLAYMS WindowsbasedChromatograms, no. stored (Chromatograms,)UnlimitedOptional storage (DATA MANAGEMENT)YesPUMPESA582Type (CONFIGURATION)Dual piston,Pump heads (PUMP)2Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications. 0.0019.999Flow increm, ml/min (PUMP)0.001Flow precision, % (ELUENT PUMP)0.3Flow accuracy, % (ELUENT PUMP)1Max pressure, psi (PUMP)5000Max/min pressure switches (Max/min pressure)YesGradient capability (PUMP)Optional with secondSolvents (PUMP)1 isocraticOTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro-COLUMN (SPECIFICATIONS) MODELMETA250 : MICRODI-Construction (ROTOR)Stainless steelLength/internal Diameter, mm (UMBILICAL CORD)250: 150: 80: 150Particle size, µm (SPECIFICATIONS)37320Particle type (COLUMN)Silica, polymericSorbent type (SPECIFICATIONS) Reverse phase (COLUMN)C18, C8, proprietaryOTHER SPECIFICATIONS (AIR SUPPLY)Manual injector.CE MARK (MDD) (Interference compensation)Yes
MODELCOULOCHEM II HPLC SYSTEMDETECTOR (SCATTERED LIGHT) MODELUV/VIS MODEL 522Wavelengths, nm (OPERATING)190800 programmableDrift, absorb/hr (DETECTOR)<0.0002Noise, aufs (DETECTOR)<±0.00001Flow cell vol, µl (DETECTOR)0.2515Cell pathlength, mm (DETECTOR)210, varies withAvail absorb, aufs (DETECTOR)0.00053Recorder output (DETECTOR)SelectableEvent marker (DETECTOR)YesSYSTEM CONFIGURATION Design (SYSTEM CONFIGURATION)Modular, isocraticstd configurationDepends on configSAMPLE INJECTORAutosampler - for details please see comments. 542 AutosamplerFixed loop or variable (Fixed loop or)VariableManual or automatic (SYSTEM CONFIGURATION)AutomaticSAMPLE VOLUME, µL1Amount of vials (SYSTEM CONFIGURATION)24,84,96Injections/sample (SYSTEM CONFIGURATION)9Perfomance time, min (SYSTEM CONFIGURATION)9 hr 59 min 59 secMaximal pressure (SYSTEM CONFIGURATION)5000Auto flushing (SYSTEM CONFIGURATION)YesStandard vial (SYSTEM CONFIGURATION)4 typesKind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10 mLDATA MANAGEMENT MODELELITE EZCHROM FORChannels (POWER NEEDED)4DISPLAYMS WindowsbasedChromatograms, no. stored (Chromatograms,)UnlimitedOptional storage (DATA MANAGEMENT)YesPUMPESA582Type (CONFIGURATION)Dual piston,Pump heads (PUMP)2Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications. 0.0019.999Flow increm, ml/min (PUMP)0.001Flow precision, % (ELUENT PUMP)0.3Flow accuracy, % (ELUENT PUMP)1Max pressure, psi (PUMP)5000Max/min pressure switches (Max/min pressure)YesGradient capability (PUMP)Optional with secondSolvents (PUMP)1 isocraticOTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro-COLUMN (SPECIFICATIONS) MODELMETA250 : MICRODI-Construction (ROTOR)Stainless steelLength/internal Diameter, mm (UMBILICAL CORD)250: 150: 80: 150Particle size, µm (SPECIFICATIONS)37320Particle type (COLUMN)Silica, polymericSorbent type (SPECIFICATIONS) Reverse phase (COLUMN)C18, C8, proprietaryOTHER SPECIFICATIONS (AIR SUPPLY)Manual injector.CE MARK (MDD) (Interference compensation)Yes
MODELCOULOCHEM II HPLC SYSTEMDETECTOR (SCATTERED LIGHT) MODELUV/VIS MODEL 522Wavelengths, nm (OPERATING)190800 programmableDrift, absorb/hr (DETECTOR)<0.0002Noise, aufs (DETECTOR)<±0.00001Flow cell vol, µl (DETECTOR)0.2515Cell pathlength, mm (DETECTOR)210, varies withAvail absorb, aufs (DETECTOR)0.00053Recorder output (DETECTOR)SelectableEvent marker (DETECTOR)YesSYSTEM CONFIGURATION Design (SYSTEM CONFIGURATION)Modular, isocraticstd configurationDepends on configSAMPLE INJECTORAutosampler - for details please see comments. 542 AutosamplerFixed loop or variable (Fixed loop or)VariableManual or automatic (SYSTEM CONFIGURATION)AutomaticSAMPLE VOLUME, µL1Amount of vials (SYSTEM CONFIGURATION)24,84,96Injections/sample (SYSTEM CONFIGURATION)9Perfomance time, min (SYSTEM CONFIGURATION)9 hr 59 min 59 secMaximal pressure (SYSTEM CONFIGURATION)5000Auto flushing (SYSTEM CONFIGURATION)YesStandard vial (SYSTEM CONFIGURATION)4 typesKind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10 mLDATA MANAGEMENT MODELELITE EZCHROM FORChannels (POWER NEEDED)4DISPLAYMS WindowsbasedChromatograms, no. stored (Chromatograms,)UnlimitedOptional storage (DATA MANAGEMENT)YesPUMPESA582Type (CONFIGURATION)Dual piston,Pump heads (PUMP)2Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications. 0.0019.999Flow increm, ml/min (PUMP)0.001Flow precision, % (ELUENT PUMP)0.3Flow accuracy, % (ELUENT PUMP)1Max pressure, psi (PUMP)5000Max/min pressure switches (Max/min pressure)YesGradient capability (PUMP)Optional with secondSolvents (PUMP)1 isocraticOTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro-COLUMN (SPECIFICATIONS) MODELMETA250 : MICRODI-Construction (ROTOR)Stainless steelLength/internal Diameter, mm (UMBILICAL CORD)250: 150: 80: 150Particle size, µm (SPECIFICATIONS)37320Particle type (COLUMN)Silica, polymericSorbent type (SPECIFICATIONS) Reverse phase (COLUMN)C18, C8, proprietaryOTHER SPECIFICATIONS (AIR SUPPLY)Manual injector.CE MARK (MDD) (Interference compensation)Yes
Exhibition system consisting of:2x CP-14 cascade pump, 0.001–10 ml/minMax. pressure: 25 MPa / 20 MPaFlow range: 0.001–10 ml/minFlow per stroke: 69 µlFlow accuracy: ± 0.5%Features: Active pulse reduction, flow compensation, pressure loss compensation, dosing with fixed volume1x GE-11 gradient controllerAn easy-to-program controller for gradient flow applications with 2 or more pumps.Compatible with FLOM pumps:HI-12-33HP-12-33AI seriesKP seriesSP seriesCP-14
DUAL PUMP KP-12 seriesDesigned for standard HPLC applications, KP-12 offers pressure monitoring, dosing mode, stable pressure flow and pressure limit for column protection.FEATURESCompact designFlow pressure sensor for pressure monitoringPressure limiter for column protectionDosing modeNon-metal PEEK pump availableCommunication terminal for remote pump operationThree pump models available for micro, analytical and preparative applications.Model No.KP1201KP1213KP1233Max. Pressure (MPa)20(PEEK) / 25(S.Steel)20(PEEK) / 25(S.Steel)5Flow Rate Range0.001 ~ 1.00 mL/min0.01 ~ 10.00 mL/min0.1 ~ 50.0 mL/minFlow Volume Per Stroke4 µl32 µI154 µIFlow Volume Accuracy+0.3% Special FunctionsFlow Volume Calibration, Dispensing Mode, Flow Pressure Calibration, Constant Pressure FlowPressure Display Accuracy+ 5% Wetted MaterialsS.Steel or PEEK, Sapphire, Ruby, PTFE, PCTFE Remote Input/OutputInput PUMP ON/OFF, Flow Volume (BCD) (420 mA analogue input optional), Output: ErrorCommunication PortN/A Dimensions (mm)144(H) X 79(W) X 285(D) WeightAppr. 3.5 kg
PCS PUMP SP-11 seriesSingle plunger pumps with latest technology. Delivers reliable performance for simple solvent flow operation.FEATURESCompact designQuick plunger return for shorter flow interruptionPressure limiter for column protectionDosing modeNon-metal PEEK pump availableThree pump models available for micro, analytical and preparative applicationsModel No.SP12 MSP1212SP1213SP1232SP1233Max. Pressure (MPa)20 MPa20 MPa10 MPa5 MPa2 MPaFlow Rate Range0.01 ~ 1.00 mL/min0.01 ~ 2.00 mL/min0.1 ~ 5.00 mL/min0.1 ~ 10.0 mL/min0.1 ~ 20.0 mL/minPlunger DiameterØ 2Ø 3.2Ø 7Plunger Stroke2 mm2 mm4 mm2 mm4 mmFlow Volume Per Stroke8µl16µl32µl77µl154µlFlow Volume Accuracy+ 0.5% Special FunctionsPulse Reduction Mode, Dispensing Mode (0.01 or 0.11000 mL)Wetted MaterialsS.Steel or PEEK, Sapphire, Ruby, PTFE, PCTFERemote Input/OutputInput: PUMP ON/OFF, Flow Volume (BCD) (420 mA analogue input optional) Output: ErrorDimensions (mm)144(H) X 79(W) X 285(D) WeightAppr. 3.0 kg
Used FLOM PI-12 STEEL pump for precise liquid dosing.
PCS PUMP SP-12 seriesSingle plunger pumps with latest technology. Delivers reliable performance for simple solvent flow operation.FEATURESCompact designQuick plunger return for shorter flow interruptionFlow pressure sensor for real-time pressure monitoringPressure limiter for column protectionDosing modeNon-metal PEEK pump availableThree pump models available for micro, analytical and preparative applicationsModel No.SP12 MSP1212SP1213SP1232SP1233Max. Pressure (MPa)20 MPa20 MPa10 MPa5 MPa2 MPaFlow Rate Range0.01 ~ 1.00 mL/min0.01 ~ 2.00 mL/min0.1 ~ 5.00 mL/min0.1 ~ 10.0 mL/min0.1 ~ 20.0 mL/minPlunger Diameterφ 2φ 3.27 φPlunger Stroke2 mm2 mm4 mm2 mm4 mmFlow Volume Per Stroke8µl16µl32µl77µl154µlFlow Volume Accuracy+ 0.5% Special FunctionsFlow Volume Calibration, Flow Pressure Calibration, Flow Pressure Limit, Pulse ReductionMode, Dispensing Mode (0.01 or 0.11000 mL)Wetted MaterialsS.Steel or PEEK, Sapphire, Ruby, PTFE, PCTFERemote Input/OutputInput: PUMP ON/OFF, Flow Volume (BCD) (420 mA analogue input optional) Output: ErrorDimensions (mm)144(H) X 79(W) X 285(D) WeightAppr. 3.0 kg
4 linesFlow up to 10 ml/min, optimal below 3 ml/min
Complete system for the purification of natural substancesThe system consists of:Rotary evaporatorBase unitEvaporator flask, amber glass, 20 LAutomatic module with residue extractionVacuum pump incl. condensate coolerCirculating cooler2 x temperature control fluid 20LBoiling point sensor2x capillary heaterCappilary mounting set for XL glass setsHolderDelivery by freight forwarder
The PrepStar SD-2 Solvent Delivery Module is designed to meet the needs of scientists and engineers who require the ability to deliver solvents at high flow rates (up to 800 mL/min) at elevated pressures.SpecificationsGeneral Specifications- Compact, modular, benchtop design- Maximum operating pressure 800 - 2500 psi (165 bar).Solvent Delivery Module Pump- Includes all general specifications listed above- Duplex zirconia plunger pump- Titanium pump heads- Flow Rate: SD-2 80 to 800 mL/min (upper flow rate limit is dependent onsolvent viscosity)- Pressure monitor (displayed on control panel)Installation Requirements- Power: 230 Vac, 50/60 Hz, 1000 VAPhysical Specifications- Solvent Delivery Module: 11.5" W x 7.75 H x 20.25" D (29.2 cm x 19.7 cm x 57.5 cm)- Weight: approximately 60 lb (27 kg).