AB Sciex API 4000
Used and refurbished to manufacturers specifications Sensitive results for drug developmentRobust, high-throughput efficiencyLow detection limits for trace analysisHigh-quality results for quantitation and precise identification of low abundance compounds, even in matrices like clinical samples, pesticide/drug residues, forensic toxicology samples and environmental samples Mass Accuracy / Stability 0.1 Da over 8 hours, 0.15 Da over 24 hoursMass Range 5-3,000Polarity Switching Time 700 msScan Speed (Quad) 24,000 Da/secScan Types Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRMSensitivity MRM Mode 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Price on request
AB Sciex TripleTOF 5600
condition Overhauled, tested, calibrated, top condition Year of manufacture 2007 Fulfills all manufacturer specifications Wide range of possible applications Resolution of 25,000 FWHM with a mass of 100 m/z, up to 40,000 FWHM at a mass of 950 m/z and a scan rate of 100 spectra per second
Price on request
Agilent 1100 Degasser Retrofit Kit
€1,999.00*
Rüsten Sie Ihren HP/Agilent 1100 Entgaser mit einem neuen Vakuumsystem und kleinerem Totvolumen aus.480µl Totvolumen pro Kammer für schnellen Eluentwechselalternativ mit 670µl oder 925µl Totvolumen pro Kammer für erhöhte Leistung lieferbarEinbau in nur ca. 20 MinutenVerbesserte ZHCR Vakuumpumpe (Zero Hysteresis Constant Run)Das Kit besteht aus:Vormontierte Einheit mit 4 Vakuumkammern, der Vakuumpumpe und der SteuerelektronikAnschlusskabel für die Spannungsversorgungausführliche EinbauanleitungAllgemeine Spezifikationen:Material des Entgaserschlauches: Teflon® AFEntgaserkammer Maximaldruck: 70 PSIG (priming pressure)Benetzte Materialien: Teflon® AF, PEEK und TefzelEntgasergehäuse: PPS (PolyPhenyleneSulphide) und Edelstahl
Agilent 1220 Infinity II (G4294B)
Binäre Gradientenpumpe mit Degasser, max. 600 barVialsampler, p max. 600 bar - ohne ThermostatSäulenofen, max 80°C, 6µL Totvolumen, für 1 Säule max. 25cmDAD Detektor G1315D, 80 Hz mit Standard Flusszelle G1315-60022Accessory Kit G4290-68755NEU, Ausstellunggsstück, Listenpreis: 56.000 EUR netto (Dez. 2022)
Price on request
CTC HTSLC-PAL for HPLC and microflow HPLC with Peltier cooling
For your HPLC and Microflow-HPLC, TOP condition, with Peltier cooling, 3 drawers for 2 x wellplates or 2 x 49 1.5ml vials, with 2 injector valves for analytical and prep. samples.
Price on request
CTC HTSLC-PAL short for HPLC and microflow HPLC with Peltier cooling
For your HPLC and microflow HPLC, TOP condition, with Peltier cooling, 3 drawers each for 2 x wellplates or 2 x 49 1.5 ml vials, with 2 injector valves for analytical and prep. samples.
Price on request
E2M28 generalüberholt im Tausch
E2M28 Vorpumpe im Austausch ohne Abluftfiltergeneralüberholt durch externen Servicepartnermit Prüfprotokoll und 24h Test
Price on request
ECODRY 65 plus (refurbished) - Mehrstufige Wälzkolbenpumpe
New instrumentTechnische Daten:Max. Saugvermögen ohne Gasballast: 55 m³/hEnddruck ohne Gasballast: 3 x 10-2 mbarLeckrate: < 1E-5 mbar l/sWasserdampfkapazität (mit Gasballast): 500 g/hSchalldruckpegel bei Enddruck: 52 dB(A)Gewicht: 43 kgAbmessungen (BxLxH): 320 x 623 x 298 mm³Schutzart: IP 42Ansaugflansch: DN40 ISO-KFAuslassflansch: DN16 ISO-KFKühlung: Luft
Price on request
Edwards 18 Vakuum Pumpe
Generalüberholt mit Prüfprotokoll oder gewartet, je nach AnfrageVersand per Spedition
Price on request
Edwards E1M18 Vakuum Pumpe
Generalüberholt mit Prüfprotokoll oder gewartet, je nach AnfrageVersand per Spedition
Price on request
Edwards E1M18 Vakuum Pumpe
Generalüberholt mit Prüfprotokoll oder gewartet, je nach AnfrageVersand per Spedition
Price on request
Edwards E1M18 Vakuum Pumpe
Generalüberholt mit Prüfprotokoll oder gewartet, je nach AnfrageVersand per Spedition
Price on request
Edwards E1M18 Vakuum Pumpe
Generalüberholt mit Prüfprotokoll oder gewartet, je nach AnfrageVersand per Spedition
Price on request
ESA Corona Plus Detector
• Reliable and simple to operate.• Universal detection of nonvolatile and many semi-volatile analytes.• Four orders of magnitude dynamic range (nonlinear).• Low ng lower limits of detection.• Typically < 2% R.S.D. response variability.• Response magnitude is minimally dependent on the analyte’s chemical properties.• Broad applicability.• Isocratic and gradient compatibility.
Price on request
ESA CoulArray Heated Organizer 70-4470T
Temperature controlled enclosure for maintaining constant temperature and organizing coulometric array cells, pre-filters, column(s), manual injector valve, PEEK pulse dampers and biocompatible gradient mixers.Temperature range: + 5°C above ambient to 45°CTemperature accuracy: < 0.5°C
Price on request
ESA Coulochem II
MODELCOULOCHEM II HPLC SYSTEM
DETECTOR (SCATTERED LIGHT)
MODELUV/VIS MODEL 522
Wavelengths, nm (OPERATING)190-800programmable
Drift, absorb/hr (DETECTOR)<,0.0002
Noise, aufs (DETECTOR)<,±0.00001
Flow cell vol, µl (DETECTOR)0.25-15
Cell pathlength, mm (DETECTOR)2-10, varies with
Avail absorb, aufs (DETECTOR)0.0005-3
Recorder output (DETECTOR)Selectable
Event marker (DETECTOR)Yes
SYSTEM CONFIGURATION
Design (SYSTEM CONFIGURATION)Modular, isocratic
std configurationDepends on config
SAMPLE INJECTORAutosampler - for details please see comments.542 Autosampler
Fixed loop or
variable (Fixed loop or)Variable
Manual or automatic (SYSTEM CONFIGURATION)Automatic
SAMPLE VOLUME, µL1
Amount of vials (SYSTEM CONFIGURATION)24,84,96
Injections/sample (SYSTEM CONFIGURATION)9
Perfomance time, min (SYSTEM CONFIGURATION)9hr 59 min 59 sec
Maximal pressure (SYSTEM CONFIGURATION)5000
Auto flushing (SYSTEM CONFIGURATION)Yes
Standard vial (SYSTEM CONFIGURATION)4types
Kind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10mL
DATA MANAGEMENT
MODELELITE EZCHROM FOR
Channels (POWER NEEDED)4
DISPLAYMS Windows-based
Chromatograms,
no. stored (Chromatograms,)Unlimited
Optional storage (DATA MANAGEMENT)Yes
PUMPESA-582
Type (CONFIGURATION)Dual piston,
Pump heads (PUMP)2
Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications.0.001-9.999
Flow increm, ml/min (PUMP)0.001
Flow precision, % (ELUENT PUMP)0.3
Flow accuracy, % (ELUENT PUMP)1
Max pressure, psi (PUMP)5000
Max/min pressure
switches (Max/min pressure)Yes
Gradient capability (PUMP)Optional with second
Solvents (PUMP)1isocratic
OTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro-
COLUMN (SPECIFICATIONS)
MODELMETA-250 : MICRODI-
Construction (ROTOR)Stainless steel
Length/internal
Diameter, mm (UMBILICAL CORD)250:150:80:150
Particle size, µm (SPECIFICATIONS)37320
Particle type (COLUMN)Silica, polymeric
Sorbent type (SPECIFICATIONS)
Reverse phase (COLUMN)C18, C8, proprietary
OTHER SPECIFICATIONS (AIR SUPPLY)Manual injector.
CE MARK (MDD) (Interference compensation)Yes
Price on request
ESA Coulochem II
MODELCOULOCHEM II HPLC SYSTEM
DETECTOR (SCATTERED LIGHT)
MODELUV/VIS MODEL 522
Wavelengths, nm (OPERATING)190-800programmable
Drift, absorb/hr (DETECTOR)<0.0002
Noise, aufs (DETECTOR)<±0.00001
Flow cell vol, µl (DETECTOR)0.25-15
Cell pathlength, mm (DETECTOR)2-10, varies with
Avail absorb, aufs (DETECTOR)0.0005-3
Recorder output (DETECTOR)Selectable
Event marker (DETECTOR)Yes
SYSTEM CONFIGURATION
Design (SYSTEM CONFIGURATION)Modular, isocratic
std configurationDepends on config
SAMPLE INJECTORAutosampler - for details please see comments.542 Autosampler
Fixed loop or
variable (Fixed loop or)Variable
Manual or automatic (SYSTEM CONFIGURATION)Automatic
SAMPLE VOLUME, µL1
Amount of vials (SYSTEM CONFIGURATION)24,84,96
Injections/sample (SYSTEM CONFIGURATION)9
Perfomance time, min (SYSTEM CONFIGURATION)9hr 59 min 59 sec
Maximal pressure (SYSTEM CONFIGURATION)5000
Auto flushing (SYSTEM CONFIGURATION)Yes
Standard vial (SYSTEM CONFIGURATION)4types
Kind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10mL
DATA MANAGEMENT
MODELELITE EZCHROM FOR
Channels (POWER NEEDED)4
DISPLAYMS Windows-based
Chromatograms,
no. stored (Chromatograms,)Unlimited
Optional storage (DATA MANAGEMENT)Yes
PUMPESA-582
Type (CONFIGURATION)Dual piston,
Pump heads (PUMP)2
Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications.0.001-9.999
Flow increm, ml/min (PUMP)0.001
Flow precision, % (ELUENT PUMP)0.3
Flow accuracy, % (ELUENT PUMP)1
Max pressure, psi (PUMP)5000
Max/min pressure
switches (Max/min pressure)Yes
Gradient capability (PUMP)Optional with second
Solvents (PUMP)1isocratic
OTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro-
COLUMN (SPECIFICATIONS)
MODELMETA-250 : MICRODI-
Construction (ROTOR)Stainless steel
Length/internal
Diameter, mm (UMBILICAL CORD)250:150:80:150
Particle size, µm (SPECIFICATIONS)37320
Particle type (COLUMN)Silica, polymeric
Sorbent type (SPECIFICATIONS)
Reverse phase (COLUMN)C18, C8, proprietary
OTHER SPECIFICATIONS (AIR SUPPLY)Manual injector.
CE MARK (MDD) (Interference compensation)Yes
Price on request
ESA Coulochem II
MODELCOULOCHEM II HPLC SYSTEM
DETECTOR (SCATTERED LIGHT)
MODELUV/VIS MODEL 522
Wavelengths, nm (OPERATING)190-800programmable
Drift, absorb/hr (DETECTOR)<0.0002
Noise, aufs (DETECTOR)<±0.00001
Flow cell vol, µl (DETECTOR)0.25-15
Cell pathlength, mm (DETECTOR)2-10, varies with
Avail absorb, aufs (DETECTOR)0.0005-3
Recorder output (DETECTOR)Selectable
Event marker (DETECTOR)Yes
SYSTEM CONFIGURATION
Design (SYSTEM CONFIGURATION)Modular, isocratic
std configurationDepends on config
SAMPLE INJECTORAutosampler - for details please see comments.542 Autosampler
Fixed loop or
variable (Fixed loop or)Variable
Manual or automatic (SYSTEM CONFIGURATION)Automatic
SAMPLE VOLUME, µL1
Amount of vials (SYSTEM CONFIGURATION)24,84,96
Injections/sample (SYSTEM CONFIGURATION)9
Perfomance time, min (SYSTEM CONFIGURATION)9hr 59 min 59 sec
Maximal pressure (SYSTEM CONFIGURATION)5000
Auto flushing (SYSTEM CONFIGURATION)Yes
Standard vial (SYSTEM CONFIGURATION)4types
Kind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10mL
DATA MANAGEMENT
MODELELITE EZCHROM FOR
Channels (POWER NEEDED)4
DISPLAYMS Windows-based
Chromatograms,
no. stored (Chromatograms,)Unlimited
Optional storage (DATA MANAGEMENT)Yes
PUMPESA-582
Type (CONFIGURATION)Dual piston,
Pump heads (PUMP)2
Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications.0.001-9.999
Flow increm, ml/min (PUMP)0.001
Flow precision, % (ELUENT PUMP)0.3
Flow accuracy, % (ELUENT PUMP)1
Max pressure, psi (PUMP)5000
Max/min pressure
switches (Max/min pressure)Yes
Gradient capability (PUMP)Optional with second
Solvents (PUMP)1isocratic
OTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro-
COLUMN (SPECIFICATIONS)
MODELMETA-250 : MICRODI-
Construction (ROTOR)Stainless steel
Length/internal
Diameter, mm (UMBILICAL CORD)250:150:80:150
Particle size, µm (SPECIFICATIONS)37320
Particle type (COLUMN)Silica, polymeric
Sorbent type (SPECIFICATIONS)
Reverse phase (COLUMN)C18, C8, proprietary
OTHER SPECIFICATIONS (AIR SUPPLY)Manual injector.
CE MARK (MDD) (Interference compensation)Yes
Price on request
ESA Coulochem II Model 5200A
MODELCOULOCHEM II HPLC SYSTEM
DETECTOR (SCATTERED LIGHT)
MODELUV/VIS MODEL 522
Wavelengths, nm (OPERATING)190-800programmable
Drift, absorb/hr (DETECTOR)<0.0002
Noise, aufs (DETECTOR)<±0.00001
Flow cell vol, µl (DETECTOR)0.25-15
Cell pathlength, mm (DETECTOR)2-10, varies with
Avail absorb, aufs (DETECTOR)0.0005-3
Recorder output (DETECTOR)Selectable
Event marker (DETECTOR)Yes
SYSTEM CONFIGURATION
Design (SYSTEM CONFIGURATION)Modular, isocratic
std configurationDepends on config
SAMPLE INJECTORAutosampler - for details please see comments.542 Autosampler
Fixed loop or
variable (Fixed loop or)Variable
Manual or automatic (SYSTEM CONFIGURATION)Automatic
SAMPLE VOLUME, µL1
Amount of vials (SYSTEM CONFIGURATION)24,84,96
Injections/sample (SYSTEM CONFIGURATION)9
Perfomance time, min (SYSTEM CONFIGURATION)9hr 59 min 59 sec
Maximal pressure (SYSTEM CONFIGURATION)5000
Auto flushing (SYSTEM CONFIGURATION)Yes
Standard vial (SYSTEM CONFIGURATION)4types
Kind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10mL
DATA MANAGEMENT
MODELELITE EZCHROM FOR
Channels (POWER NEEDED)4
DISPLAYMS Windows-based
Chromatograms,
no. stored (Chromatograms,)Unlimited
Optional storage (DATA MANAGEMENT)Yes
PUMPESA-582
Type (CONFIGURATION)Dual piston,
Pump heads (PUMP)2
Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications.0.001-9.999
Flow increm, ml/min (PUMP)0.001
Flow precision, % (ELUENT PUMP)0.3
Flow accuracy, % (ELUENT PUMP)1
Max pressure, psi (PUMP)5000
Max/min pressure
switches (Max/min pressure)Yes
Gradient capability (PUMP)Optional with second
Solvents (PUMP)1isocratic
OTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro-
COLUMN (SPECIFICATIONS)
MODELMETA-250 : MICRODI-
Construction (ROTOR)Stainless steel
Length/internal
Diameter, mm (UMBILICAL CORD)250:150:80:150
Particle size, µm (SPECIFICATIONS)37320
Particle type (COLUMN)Silica, polymeric
Sorbent type (SPECIFICATIONS)
Reverse phase (COLUMN)C18, C8, proprietary
OTHER SPECIFICATIONS (AIR SUPPLY)Manual injector.
CE MARK (MDD) (Interference compensation)Yes
Price on request