Filter products
Upgrade your HP/Agilent 1100 degasser with a new vacuum system and smaller dead volume.480µl dead volume per chamber for fast eluent changeAlternatively available with 670µl or 925µl dead volume per chamber for increased performanceInstallation in only approx. 20 minutesImproved ZHCR vacuum pump (Zero Hysteresis Constant Run)The kit consists of:Pre-assembled unit with 4 vacuum chambers, vacuum pump, and control electronicsConnection cable for power supplyDetailed installation instructionsGeneral specifications:Degasser hose material: Teflon® AFDegasser chamber maximum pressure: 70 PSIG (priming pressure)Wetted materials: Teflon® AF, PEEK, and TefzelDegasser housing: PPS (polyphenylene sulfide) and stainless steelTranslated with DeepL.com (free version)
Binäre Gradientenpumpe mit Degasser, max. 600 barVialsampler, p max. 600 bar - ohne ThermostatSäulenofen, max 80°C, 6µL Totvolumen, für 1 Säule max. 25cmDAD Detektor G1315D, 80 Hz mit Standard Flusszelle G1315-60022Accessory Kit G4290-68755NEU, Ausstellunggsstück, Listenpreis: 56.000 EUR netto (Dez. 2022)
2-position/6-port injection valve 600 barNew & in original packagingDelivery with cable, but without capillary.
For your HPLC and Microflow-HPLC, TOP condition, with Peltier cooling, 3 drawers for 2 x wellplates or 2 x 49 1.5ml vials, with 2 injector valves for analytical and prep. samples.
For your HPLC and microflow HPLC, TOP condition, with Peltier cooling, 3 drawers each for 2 x wellplates or 2 x 49 1.5 ml vials, with 2 injector valves for analytical and prep. samples.
• Reliable and simple to operate.• Universal detection of nonvolatile and many semi-volatile analytes.• Four orders of magnitude dynamic range (nonlinear).• Low ng lower limits of detection.• Typically < 2% R.S.D. response variability.• Response magnitude is minimally dependent on the analyte’s chemical properties.• Broad applicability.• Isocratic and gradient compatibility.
Temperature controlled enclosure for maintaining constant temperature and organizing coulometric array cells, pre-filters, column(s), manual injector valve, PEEK pulse dampers and biocompatible gradient mixers.Temperature range: + 5°C above ambient to 45°CTemperature accuracy: < 0.5°C
MODELCOULOCHEM II HPLC SYSTEM DETECTOR (SCATTERED LIGHT) MODELUV/VIS MODEL 522 Wavelengths, nm (OPERATING)190-800programmable Drift, absorb/hr (DETECTOR)<,0.0002 Noise, aufs (DETECTOR)<,±0.00001 Flow cell vol, µl (DETECTOR)0.25-15 Cell pathlength, mm (DETECTOR)2-10, varies with Avail absorb, aufs (DETECTOR)0.0005-3 Recorder output (DETECTOR)Selectable Event marker (DETECTOR)Yes SYSTEM CONFIGURATION Design (SYSTEM CONFIGURATION)Modular, isocratic std configurationDepends on config SAMPLE INJECTORAutosampler - for details please see comments.542 Autosampler Fixed loop or variable (Fixed loop or)Variable Manual or automatic (SYSTEM CONFIGURATION)Automatic SAMPLE VOLUME, µL1 Amount of vials (SYSTEM CONFIGURATION)24,84,96 Injections/sample (SYSTEM CONFIGURATION)9 Perfomance time, min (SYSTEM CONFIGURATION)9hr 59 min 59 sec Maximal pressure (SYSTEM CONFIGURATION)5000 Auto flushing (SYSTEM CONFIGURATION)Yes Standard vial (SYSTEM CONFIGURATION)4types Kind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10mL DATA MANAGEMENT MODELELITE EZCHROM FOR Channels (POWER NEEDED)4 DISPLAYMS Windows-based Chromatograms, no. stored (Chromatograms,)Unlimited Optional storage (DATA MANAGEMENT)Yes PUMPESA-582 Type (CONFIGURATION)Dual piston, Pump heads (PUMP)2 Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications.0.001-9.999 Flow increm, ml/min (PUMP)0.001 Flow precision, % (ELUENT PUMP)0.3 Flow accuracy, % (ELUENT PUMP)1 Max pressure, psi (PUMP)5000 Max/min pressure switches (Max/min pressure)Yes Gradient capability (PUMP)Optional with second Solvents (PUMP)1isocratic OTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro- COLUMN (SPECIFICATIONS) MODELMETA-250 : MICRODI- Construction (ROTOR)Stainless steel Length/internal Diameter, mm (UMBILICAL CORD)250:150:80:150 Particle size, µm (SPECIFICATIONS)37320 Particle type (COLUMN)Silica, polymeric Sorbent type (SPECIFICATIONS) Reverse phase (COLUMN)C18, C8, proprietary OTHER SPECIFICATIONS (AIR SUPPLY)Manual injector. CE MARK (MDD) (Interference compensation)Yes
MODELCOULOCHEM II HPLC SYSTEM DETECTOR (SCATTERED LIGHT) MODELUV/VIS MODEL 522 Wavelengths, nm (OPERATING)190-800programmable Drift, absorb/hr (DETECTOR)<0.0002 Noise, aufs (DETECTOR)<±0.00001 Flow cell vol, µl (DETECTOR)0.25-15 Cell pathlength, mm (DETECTOR)2-10, varies with Avail absorb, aufs (DETECTOR)0.0005-3 Recorder output (DETECTOR)Selectable Event marker (DETECTOR)Yes SYSTEM CONFIGURATION Design (SYSTEM CONFIGURATION)Modular, isocratic std configurationDepends on config SAMPLE INJECTORAutosampler - for details please see comments.542 Autosampler Fixed loop or variable (Fixed loop or)Variable Manual or automatic (SYSTEM CONFIGURATION)Automatic SAMPLE VOLUME, µL1 Amount of vials (SYSTEM CONFIGURATION)24,84,96 Injections/sample (SYSTEM CONFIGURATION)9 Perfomance time, min (SYSTEM CONFIGURATION)9hr 59 min 59 sec Maximal pressure (SYSTEM CONFIGURATION)5000 Auto flushing (SYSTEM CONFIGURATION)Yes Standard vial (SYSTEM CONFIGURATION)4types Kind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10mL DATA MANAGEMENT MODELELITE EZCHROM FOR Channels (POWER NEEDED)4 DISPLAYMS Windows-based Chromatograms, no. stored (Chromatograms,)Unlimited Optional storage (DATA MANAGEMENT)Yes PUMPESA-582 Type (CONFIGURATION)Dual piston, Pump heads (PUMP)2 Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications.0.001-9.999 Flow increm, ml/min (PUMP)0.001 Flow precision, % (ELUENT PUMP)0.3 Flow accuracy, % (ELUENT PUMP)1 Max pressure, psi (PUMP)5000 Max/min pressure switches (Max/min pressure)Yes Gradient capability (PUMP)Optional with second Solvents (PUMP)1isocratic OTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro- COLUMN (SPECIFICATIONS) MODELMETA-250 : MICRODI- Construction (ROTOR)Stainless steel Length/internal Diameter, mm (UMBILICAL CORD)250:150:80:150 Particle size, µm (SPECIFICATIONS)37320 Particle type (COLUMN)Silica, polymeric Sorbent type (SPECIFICATIONS) Reverse phase (COLUMN)C18, C8, proprietary OTHER SPECIFICATIONS (AIR SUPPLY)Manual injector. CE MARK (MDD) (Interference compensation)Yes
MODELCOULOCHEM II HPLC SYSTEM DETECTOR (SCATTERED LIGHT) MODELUV/VIS MODEL 522 Wavelengths, nm (OPERATING)190-800programmable Drift, absorb/hr (DETECTOR)<0.0002 Noise, aufs (DETECTOR)<±0.00001 Flow cell vol, µl (DETECTOR)0.25-15 Cell pathlength, mm (DETECTOR)2-10, varies with Avail absorb, aufs (DETECTOR)0.0005-3 Recorder output (DETECTOR)Selectable Event marker (DETECTOR)Yes SYSTEM CONFIGURATION Design (SYSTEM CONFIGURATION)Modular, isocratic std configurationDepends on config SAMPLE INJECTORAutosampler - for details please see comments.542 Autosampler Fixed loop or variable (Fixed loop or)Variable Manual or automatic (SYSTEM CONFIGURATION)Automatic SAMPLE VOLUME, µL1 Amount of vials (SYSTEM CONFIGURATION)24,84,96 Injections/sample (SYSTEM CONFIGURATION)9 Perfomance time, min (SYSTEM CONFIGURATION)9hr 59 min 59 sec Maximal pressure (SYSTEM CONFIGURATION)5000 Auto flushing (SYSTEM CONFIGURATION)Yes Standard vial (SYSTEM CONFIGURATION)4types Kind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10mL DATA MANAGEMENT MODELELITE EZCHROM FOR Channels (POWER NEEDED)4 DISPLAYMS Windows-based Chromatograms, no. stored (Chromatograms,)Unlimited Optional storage (DATA MANAGEMENT)Yes PUMPESA-582 Type (CONFIGURATION)Dual piston, Pump heads (PUMP)2 Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications.0.001-9.999 Flow increm, ml/min (PUMP)0.001 Flow precision, % (ELUENT PUMP)0.3 Flow accuracy, % (ELUENT PUMP)1 Max pressure, psi (PUMP)5000 Max/min pressure switches (Max/min pressure)Yes Gradient capability (PUMP)Optional with second Solvents (PUMP)1isocratic OTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro- COLUMN (SPECIFICATIONS) MODELMETA-250 : MICRODI- Construction (ROTOR)Stainless steel Length/internal Diameter, mm (UMBILICAL CORD)250:150:80:150 Particle size, µm (SPECIFICATIONS)37320 Particle type (COLUMN)Silica, polymeric Sorbent type (SPECIFICATIONS) Reverse phase (COLUMN)C18, C8, proprietary OTHER SPECIFICATIONS (AIR SUPPLY)Manual injector. CE MARK (MDD) (Interference compensation)Yes
MODELCOULOCHEM II HPLC SYSTEM DETECTOR (SCATTERED LIGHT) MODELUV/VIS MODEL 522 Wavelengths, nm (OPERATING)190-800programmable Drift, absorb/hr (DETECTOR)<0.0002 Noise, aufs (DETECTOR)<±0.00001 Flow cell vol, µl (DETECTOR)0.25-15 Cell pathlength, mm (DETECTOR)2-10, varies with Avail absorb, aufs (DETECTOR)0.0005-3 Recorder output (DETECTOR)Selectable Event marker (DETECTOR)Yes SYSTEM CONFIGURATION Design (SYSTEM CONFIGURATION)Modular, isocratic std configurationDepends on config SAMPLE INJECTORAutosampler - for details please see comments.542 Autosampler Fixed loop or variable (Fixed loop or)Variable Manual or automatic (SYSTEM CONFIGURATION)Automatic SAMPLE VOLUME, µL1 Amount of vials (SYSTEM CONFIGURATION)24,84,96 Injections/sample (SYSTEM CONFIGURATION)9 Perfomance time, min (SYSTEM CONFIGURATION)9hr 59 min 59 sec Maximal pressure (SYSTEM CONFIGURATION)5000 Auto flushing (SYSTEM CONFIGURATION)Yes Standard vial (SYSTEM CONFIGURATION)4types Kind of vial (SYSTEM CONFIGURATION)0.5,1.5, 4,10mL DATA MANAGEMENT MODELELITE EZCHROM FOR Channels (POWER NEEDED)4 DISPLAYMS Windows-based Chromatograms, no. stored (Chromatograms,)Unlimited Optional storage (DATA MANAGEMENT)Yes PUMPESA-582 Type (CONFIGURATION)Dual piston, Pump heads (PUMP)2 Flow range, ml/min (ELUENT PUMP)Up to 10 - please see comments for detailed specifications.0.001-9.999 Flow increm, ml/min (PUMP)0.001 Flow precision, % (ELUENT PUMP)0.3 Flow accuracy, % (ELUENT PUMP)1 Max pressure, psi (PUMP)5000 Max/min pressure switches (Max/min pressure)Yes Gradient capability (PUMP)Optional with second Solvents (PUMP)1isocratic OTHER DETECTORS (DATA MANAGEMENT)Coulochem Electro- COLUMN (SPECIFICATIONS) MODELMETA-250 : MICRODI- Construction (ROTOR)Stainless steel Length/internal Diameter, mm (UMBILICAL CORD)250:150:80:150 Particle size, µm (SPECIFICATIONS)37320 Particle type (COLUMN)Silica, polymeric Sorbent type (SPECIFICATIONS) Reverse phase (COLUMN)C18, C8, proprietary OTHER SPECIFICATIONS (AIR SUPPLY)Manual injector. CE MARK (MDD) (Interference compensation)Yes
Ausstellungssystem bestehend aus:2x Cascade Pump CP-14, 0,001-10 mL/minMax. pressure: 25 MPa / 20 MPaFlow rate range: 0,001-10 mL/minFlow per stroke: 69 µLFlow accuracy: ± 0,5%Features: Active pulse reduction, Flow volume compensation, Pressure loss compensation, Set volume dispensing1x Gradient Controller GE-11An easy to program controller for gradient flow applications using 2 or more pumps.Compatible with FLOM pumps:HI-12-33HP-12-33AI seriesKP seriesSP seriesCP-14
DUAL PUMP KP-12 seriesDesigned for standard HPLC applications, KP-12 offers pressure monitoring, dosing mode, stable pressure flow and pressure limit for column protection.FEATURESCompact designFlow pressure sensor for pressure monitoringPressure limiter for column protectionDosing modeNon-metal PEEK pump availableCommunication terminal for remote pump operationThree pump models available for micro, analytical and preparative applications. Model No.KP-12-01KP-12-13KP-12-33 Max. Pressure (MPa)20(PEEK) / 25(S.Steel)20(PEEK) / 25(S.Steel)5 Flow Rate Range0.001~1.00mL/min0.01~10.00mL/min0.1~50.0mL/min Flow Volume Per Stroke4 µl32 µI154 µI Flow Volume Accuracy+0.3% Special FunctionsFlow Volume Calibration, Dispensing Mode, Flow Pressure Calibration, Constant Pressure Flow Pressure Display Accuracy+ 5% Wetted MaterialsS.Steel or PEEK, Sapphire, Ruby, PTFE, PCTFE Remote Input/OutputInput PUMP ON/OFF, Flow Volume (BCD) (4-20mA analogue input optional), Output: Error Communication PortN/A Dimensions (mm)144(H) X 79(W) X 285(D) WeightAppr. 3.5kg
PCS PUMP SP-11 seriesSingle plunger pumps with latest technology. Delivers reliable performance for simple solvent flow operation.FEATURESCompact designQuick plunger return for shorter flow interruptionPressure limiter for column protectionDosing modeNon-metal PEEK pump availableThree pump models available for micro, analytical and preparative applications Model No.SP-12-MSP-12-12SP-12-13SP-12-32SP-12-33 Max. Pressure (MPa)20MPa20MPa10MPa5MPa2MPa Flow Rate Range0.01~1.00mL/min0.01~2.00mL/min0.1~5.00mL/min0.1~10.0mL/min0.1~20.0mL/min Plunger DiameterØ 2Ø 3.2Ø 7 Plunger Stroke2mm2mm4mm2mm4mm Flow Volume Per Stroke8µl16µl32µl77µl154µl Flow Volume Accuracy+ 0.5% Special FunctionsPulse Reduction Mode, Dispensing Mode (0.01 or 0.1-1000mL) Wetted MaterialsS.Steel or PEEK, Sapphire, Ruby, PTFE, PCTFE Remote Input/OutputInput: PUMP ON/OFF, Flow Volume (BCD) (4-20mA analogue input optional) Output: Error Dimensions (mm)144(H) X 79(W) X 285(D) WeightAppr. 3.0kg
PCS PUMP SP-12 seriesSingle plunger pumps with latest technology. Delivers reliable performance for simple solvent flow operation.FEATURESCompact designQuick plunger return for shorter flow interruptionFlow pressure sensor for real-time pressure monitoringPressure limiter for column protectionDosing modeNon-metal PEEK pump availableThree pump models available for micro, analytical and preparative applications Model No.SP-12-MSP-12-12SP-12-13SP-12-32SP-12-33 Max. Pressure (MPa)20MPa20MPa10MPa5MPa2MPa Flow Rate Range0.01~1.00mL/min0.01~2.00mL/min0.1~5.00mL/min0.1~10.0mL/min0.1~20.0mL/min Plunger Diameterφ 2φ 3.27 φ Plunger Stroke2mm2mm4mm2mm4mm Flow Volume Per Stroke8µl16µl32µl77µl154µl Flow Volume Accuracy+ 0.5% Special FunctionsFlow Volume Calibration, Flow Pressure Calibration, Flow Pressure Limit, Pulse ReductionMode, Dispensing Mode (0.01 or 0.1-1000mL) Wetted MaterialsS.Steel or PEEK, Sapphire, Ruby, PTFE, PCTFE Remote Input/OutputInput: PUMP ON/OFF, Flow Volume (BCD) (4-20mA analogue input optional) Output: Error Dimensions (mm)144(H) X 79(W) X 285(D) WeightAppr. 3.0kg
4 linesFlow up to 10 ml/min, optimal below 3 ml/min
The PrepStar SD-2 Solvent Delivery Module is designed to meet the needs of scientists and engineers who require the ability to deliver solvents at high flow rates (up to 800 mL/min) at elevated pressures.SpecificationsGeneral Specifications- Compact, modular, benchtop design- Maximum operating pressure 800 - 2500 psi (165 bar).Solvent Delivery Module Pump- Includes all general specifications listed above- Duplex zirconia plunger pump- Titanium pump heads- Flow Rate: SD-2 80 to 800 mL/min (upper flow rate limit is dependent onsolvent viscosity)- Pressure monitor (displayed on control panel)Installation Requirements- Power: 230 Vac, 50/60 Hz, 1000 VAPhysical Specifications- Solvent Delivery Module: 11.5" W x 7.75 H x 20.25" D (29.2 cm x 19.7 cm x 57.5 cm)- Weight: approximately 60 lb (27 kg).
Varian SD1 HPLC System consisting of:Rainin FC-1PrepStar SD1 PumpPrepStar SD1 PumpePrepStar Solvent Delivery Module Model 218Varian ProStarHP xw4400 WorkstationDell Monitor