Used and refurbished to manufacturers specificationsSensitive results for drug developmentRobust, high-throughput efficiencyLow detection limits for trace analysisHigh-quality results for quantitation and precise identification of low abundance compounds, even in matrices like clinical samples, pesticide/drug residues, forensic toxicology samples and environmental samplesMass Accuracy / Stability 0.1 Da over 8 hours, 0.15 Da over 24 hoursMass Range 5-3,000Polarity Switching Time 700 msScan Speed (Quad) 24,000 Da/secScan Types Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRMSensitivity MRM Mode 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
LC/MSn high resolutionIon Max ESI Source & HCD Collision CellTested, with warranty.Spezifikationen:Routine FT mass accuracy60,000 resolution at 1 Hz scan cycleWide dynamic rangeParallel MS and MSn analysisMultiple dissociation techniques: CID, PQD and HCDMass Range m/z 50-2000, m/z 200-4000Resolution 60,000 at m/z 400 at a scan rate of 1 Hz,min. resolution 7,500 max. resolution >100,000 at m/z 400Mass Accuracy < 3 ppm external calibration, < 2 ppm internal calibrationSensitivity sub-femtomol range for peptidesDynamic Range > 4,000 within a single scanMS Scan Power MSn , for n = 1 through 10Price plus installation.
Includes Ion Max ESI source, HCD collision cell, Thermoflex 900 chiller, and backing pumps.Fully tested with 3-month warranty.Specifications:Routine FT mass accuracy100,000 resolution at 1 Hz scan cycleWide dynamic rangeParallel MS and MSn analysisMultiple dissociation techniques: CID, PQD and HCDMass Range m/z 50-2000, m/z 200-4000Resolution 60,000 at m/z 400 at a scan rate of 1 Hz*,min. resolution 7,500 max. resolution 100,000 at m/z 400*Mass Accuracy < 3 ppm external calibration, < 1 ppm internal calibration*Sensitivity sub-femtomol range for peptidesDynamic Range > 4,000 within a single scanMS Scan Power MSn , for n = 1 through 10*The specifications of refurbished devices may vary!Price plus installation.
The API 3000 LC/MS/MS System is an enhanced high performance triple quadrupole mass spectrometer with applications in protein and peptide analysis, small molecule analysis in drug metabolism and pharmacokinetic studies, and n-in-one cassette dosing analysis.All our devices are tested, cleaned, and inspected before delivery.Device in stock, available 6–8 weeks after receipt of order.
Like-new Orbitrap HRMS instrument, manufactured in 2021, rarely used.SpecificationsDynamic range:> 5,000:1 within a spectrumMass accuracy:< 3 ppm RMS – with internal calibrationMass range:40 to 6,000 m/zResolution:max. 480,000 at 195 m/zPolarity switching:One complete scan cycle in < 1 s(one complete scan each in positive and negative modes at a resolution of 60,000)Scan rate:max. 40 Hz at a resolution of 7,500 at 200 m/zSensitivity:MS/MS: 50 fg reserpine on column, S/N 100:1 SIM: 50 fg reserpine on column, S/N 150:1Refurbished, incl. fore-pump, data acquisition system, LED monitor(HPLC / UPLC optional upon request)
Accessories:1 Measuring computer1 Keyboard1 Mouse1 MonitorIncludes 2 x Edwards E2M30 oil pumps
Orbitrap Tribrid HRMS instrument, manufactured in 2014SpecificationsMass range:m/z 50–2,000, m/z 200–4,000, up to m/z 6,000 without precursor ionOTMS resolution:15,000–500,000 (FWHM) at m/z 200Scan rate:OTMSn up to 20 Hz, ITMSn up to 20 HzOTMS mass accuracy:< 3 ppm RMS with external calibration, < 1 ppm RMS with internal calibrationMS/MS electrospray ionization (ESI) ion trap sensitivity: 2 μL of a 50 fg/μL solution of reserpine(total 100 femtograms), injected at a flow rate of 500 μL/min, produces a minimum signal-to-noise ratio of 200:1 for the transition of the isolated protonated molecular ions at m/z 609 to the two largest products, m/z 397 and m/z 448, when the mass spectrometer is operated with unit resolution in full-scan MS/MS mode, m/z 165–615. An HESI III probe is required for the test.Dynamic range:> 5,000 within a single OTMS spectrumMS scan capability: MSn, for n = 1 to 10Synchronous precursor isolation, up to 20 precursors per MSn scanMultiplexing using the ion routing multipoleUp to 10 precursors per scan using the quadrupole mass filterPolarity switching:full cycle in < 1.1 s (one full scan in positive mode and one full scan in negative mode at a resolution setting of 30,000)ETD efficiency: ETD fragmentation efficiency of >15% (infusion of 1 pmol/μL angiotensin at 3 μL/min)refurbished, incl. forepump, control computer, LED monitor(HPLC / UPLC / nanoLC optional upon request)
Orbitrap Tribrid HRMS instrument, manufactured in 2017SpecificationsMass range:m/z 50–2,000, m/z 200–4,000, up to m/z 6,000 without precursor ionOTMS resolution:15,000–500,000 (FWHM) at m/z 200Scan rate:OTMSn up to 20 Hz, ITMSn up to 20 HzOTMS mass accuracy:< 3 ppm RMS with external calibration, < 1 ppm RMS with internal calibrationMS/MS electrospray ionization (ESI) ion trap sensitivity: 2 μL of a 50 fg/μL solution of reserpine(total 100 femtograms), injected at a flow rate of 500 μL/min, produces a minimum signal-to-noise ratio of 200:1 for the transition of the isolated protonated molecular ions at m/z 609 to the two largest products, m/z 397 and m/z 448, when the mass spectrometer is operated with unit resolution in full-scan MS/MS mode, m/z 165–615. An HESI III probe is required for the test.Dynamic range:> 5,000 within a single OTMS spectrumMS scan capability: MSn, for n = 1 to 10Synchronous precursor isolation, up to 20 precursors per MSn scanMultiplexing using the ion routing multipoleUp to 10 precursors per scan using the quadrupole mass filterPolarity switching:full cycle in < 1.1 s (one full scan in positive mode and one full scan in negative mode at a resolution setting of 30,000)ETD efficiency: ETD fragmentation efficiency of >15% (infusion of 1 pmol/μL angiotensin at 3 μL/min)refurbished, incl. forepump, control computer, LED monitor(HPLC / UPLC / nanoLC optional upon request)
Two high resolution quadrupole analyzers (MS1/MS2), plus prefilters to maximize resolution and transmission while preventing contamination of the main analyzers.T-Wave™1 enabled for optimal MS/MS performance at high data acquisition rates.Low noise, off axis, long life photomultiplier detectorDigital dynamic range up to 4 x 10^6.Full scan MSProduct ion scanPrecursor ion scanConstant neutral lossSelected Ion Recording (SIR)Multiple Reaction Monitoring (MRM)Survey scan modes: Full scan MS triggered product ion scanMass range 2 to 2048 m/zScan speed Up to 10,000 Da/sExamples of achievable acquisition rates 10 scans per second (m/z 100 to 1000), 20 scans per second (m/z 50 to 500)Mass stability Mass drift is <0.1 Da over a 24 hour period
Specialized quantitative applications, including ADME screening, bioanalysis, clinical analysis, as well as food safety and environmental monitoring, require high sensitivity, high performance LC/MS/MS instrumentation. Compliance with stringent regulatory guidelines may also be necessary with these applications.Compact size - Uses only 18.9" (48 cm) of linear benchspace.T-Wave collision cell for optimum performance at fast acquisition rates and a polarityswitching time of only 20 ms ensures that the Quattro Premier XE is ideally suited to the demands of UPLC.Dynamic range—up to 5 orders of magnitude for accurate determination across a wide concentration range.Data Directed Analysis for intelligent, automated MS to MS/MS switching within a single analytical run.The new low-noise WhisperTM detector in the Quattro Premier XE provides a detectionefficiency approaching 100% for single ions. Situated after the second analyzer andfeaturing integral focusing optics, the detector‘s high voltage dynode and phosphor arepositioned 90 ̊ off-axis to eliminate neutral noise. The detector can rapidly switch polarity(20 ms), allowing the detection of both positive and negative ions in a chromatographicpeak. In addition, the detector’s robust photomultiplier tube is sealed for life in a vacuumenvelope, guaranteeing years of maintenance free service.
The Waters MicromassZQ Mass Spectrometer, the most popular single quadrupole mass spectrometer worldwide, offers characteristic performance and robustness for laboratories that require nominal mass resolution for mass confirmation applications. The ZQ Mass Spectrometer is built using the technical innovation you expect from Micromass brand products.All our devices are tested, cleaned, and inspected before delivery.Device in stock, available 6–8 weeks after receipt of order.
Waters SQ Detector (Aquity)High performance ZSpray™ dual-orthogonal API sources:1) ESI (standard)2) Multimode source – ESI/APCI/ESCi ® (standard)3) Dedicated APCI (optional)4) Dual-mode Atmospheric Pressure Photo Ionization (APPI)/APCI source (optional)5) Atmospheric Solids Analysis Probe (ASAP) (optional)Vacuum isolation valveTool free access to customer serviceable elementsPlug and play probesDe-clustering cone gasSoftware control of gas flows and heating elements
Two high resolution quadrupole analyzers (MS1/MS2), plus prefilters to maximize resolution and transmission while preventing contamination of the main analyzers.T-Wave™1 enabled for optimal MS/MS performance at high data acquisition rates.Low noise, off axis, long life photomultiplier detectorDigital dynamic range up to 4 x 10^6.Full scan MSProduct ion scanPrecursor ion scanConstant neutral lossSelected Ion Recording (SIR)Multiple Reaction Monitoring (MRM)Survey scan modes: Full scan MS triggered product ion scanMass range 2 to 2048 m/zScan speed Up to 10,000 Da/sExamples of achievable acquisition rates 10 scans per second (m/z 100 to 1000), 20 scans per second (m/z 50 to 500)Mass stability Mass drift is <0.1 Da over a 24 hour period